Draft California 2020 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 5 - Central Valley Region

Water Body Name: Plumas Lake Canal (Yuba County)
Water Body ID: CAR5152000020200129042366
Water Body Type: River & Stream
 
DECISION ID
129513
Region 5     
Plumas Lake Canal (Yuba County)
 
Pollutant: Specific Conductivity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: New Decision
Revision Status Revised
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: Insufficient information is available to determine beneficial use support for this waterbody-pollutant combination with the statistical power and confidence required by the Listing Policy. Beneficial use support will be reassessed in a future cycle, if more data are available.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation:
 
 
Line of Evidence (LOE) for Decision ID 129513, Specific Conductivity
Region 5     
Plumas Lake Canal (Yuba County)
 
LOE ID: 211698
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Water Board staff assessed SWAMP Monitoring data for Plumas Lake Canal (Yuba County) to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality threshold for SpecificConductivity.
Data Reference: Field, Habitat, Sediment, Toxicity, Water data for the 2020/2022 integrated report in Region 5.
 
SWAMP Data: SWAMP
 
Water Quality Objective/Criterion: The California Secondary MCL that is incorporated by reference in the Water Quality Control Plan, Central Valley Region Sacramento River Basin and San Joaquin River Basin for specific conductance is 900 uS/cm.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins; Fifth Edition. Revised May 2018 (with approved amendments)
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: The samples were collected at 1 monitoring site (515PLUUxx)
Temporal Representation: The samples were collected between the dates of 2012-09-21 and 2012-09-21
Environmental Conditions:
QAPP Information: SWAMP QAPrP 2008
QAPP Information Reference(s): Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program