Final California 2018 Integrated Report (303(d) List/305(b) Report)

Supporting Information

Regional Board 5 - Central Valley Region

Water Body Name: Lavezzola Creek (Sierra County)
Water Body ID: CAR5175301220110209100234
Water Body Type: River & Stream
 
DECISION ID
67912
Region 5     
Lavezzola Creek (Sierra County)
 
Pollutant: Arsenic
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 one line of evidence is necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of the one samples exceed the water quality objective for MUN, and zero of the one samples exceed the evaluation guideline for COLD.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the one samples exceed the water quality objective for MUN, and zero of the one samples exceed the evaluation guideline for COLD and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 67912, Arsenic
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 66030
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: Fixed station physical/chemical (conventional plus toxic pollutants)
Data Used to Assess Water Quality: The sample did not exceed the CTR criteria of 150 ug/L.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: California Toxics Rule lists criterion continuous concentrations (expressed as a 4-day average) for dissolved arsenic to protect aquatic life in freshwater. The CTR criteria for Arsenic is 150 ug/L.
Guideline Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Spatial Representation: Site 4 was sampled in Lavezzola Creek (Sierra County).
Temporal Representation: Sample was collected on 12/11/2004.
Environmental Conditions: None reported.
QAPP Information: Samples were collected and analyzed in accordance with Water Monitoring Quality Assurance Project Plan prepared for the Yuba Watershed Monitoring Committee (Revision 1.3) dated June 30, 2008.
QAPP Information Reference(s):
 
Line of Evidence (LOE) for Decision ID 67912, Arsenic
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 66031
 
Pollutant: Arsenic
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: Fixed station physical/chemical (conventional plus toxic pollutants)
Data Used to Assess Water Quality: The one sample did not exceed the Water Quality Objective.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses. The CA Department of Health Services maximum contamination level (MCL) thought to be protective of drinking water for arsenic is 10 ug/L.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
Objective/Criterion Reference: MCLs for Regulated Drinking Water Contaminants, California Department of Public Health.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Site 4 was sampled in Lavezzola Creek (Sierra County).
Temporal Representation: Sample was collected on 12/11/2004.
Environmental Conditions:
QAPP Information: Samples were collected and analyzed in accordance with Water Monitoring Quality Assurance Project Plan prepared for the Yuba Watershed Monitoring Committee (Revision 1.3) dated June 30, 2008.
QAPP Information Reference(s):
 
 
DECISION ID
92446
Region 5     
Lavezzola Creek (Sierra County)
 
Pollutant: Indicator Bacteria
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the twenty-nine samples exceed the water quality objective.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of twenty-nine samples exceed the water quality objective and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 92446, Indicator Bacteria
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 66032
 
Pollutant: Escherichia coli (E. coli)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 29
Number of Exceedances: 0
 
Data and Information Type: Not Specified
Data Used to Assess Water Quality: Zero of the 29 samples exceeded the e. coli objective.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses. (Water Quality Control Plan, Central Valley Region, Sacramento River and San Joaquin River Basins)
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: Single sample maximum allowable density for E. coli in freshwater is 235 MPN/100mL. USEPA Ambient Water Quality Criteria for Bacteria -1986.
Guideline Reference: Ambient Water Quality Criteria for Bacteria - 1986. EPA440/5-84-002
 
Spatial Representation: The samples were collected at SYRCL monitoring station 4, Lavezzola Creek. WBID: CAR5175301220110209100234
Temporal Representation: The samples were collected monthly between 2001 and 2006.
Environmental Conditions:
QAPP Information: This data was collected under the Water Monitoring Quality Assurance Project Plan for the Yuba Watershed Council Monitoring Committee. Rev 1.3. qa12
QAPP Information Reference(s):
 
 
DECISION ID
67913
Region 5     
Lavezzola Creek (Sierra County)
 
Pollutant: Iron
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1, one line(s) of evidence are necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the one samples exceed the Evaluation Guideline.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of one samples exceeded Evaluation Guideline and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 67913, Iron
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 66033
 
Pollutant: Iron
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 1
Number of Exceedances: 0
 
Data and Information Type: Fixed station physical/chemical (conventional plus toxic pollutants)
Data Used to Assess Water Quality: The sample did not exceed the recommended criteria of 1,000 ug/L.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: National Recommended Water Quality Criteria Continuous Concentrations are intended protect freshwater aquatic organisms from chronic exposures and are expressed as 4-day average concentrations. The recommended criteria for iron is 1,000 ug/L.
Guideline Reference: National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology
 
Spatial Representation: Site 4 was sampled in Lavezzola Creek (Sierra County).
Temporal Representation: Samples was collected on 12/11/2004.
Environmental Conditions: None reported.
QAPP Information: Samples were collected and analyzed in accordance with Water Monitoring Quality Assurance Project Plan prepared for the Yuba Watershed Monitoring Committee (Revision 1.3) dated June 30, 2008.
QAPP Information Reference(s):
 
 
DECISION ID
99678
Region 5     
Lavezzola Creek (Sierra County)
 
Pollutant: Oxygen, Dissolved
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. One of the ninety-two samples exceed the water quality objective.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. One of the ninety-two samples exceed the water quality objective and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 99678, Oxygen, Dissolved
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 59384
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 92
Number of Exceedances: 1
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: One of the 92 daily averaged samples exceeded the water quality objective for dissolved oxygen in this water body.
Data Reference: Data for Various Pollutants at Placer County Utilities, 2005-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: From the Basin Plan, the minimum level for dissolved oxygen is 7 mg/L for waters designated as COLD.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Samples collected at site 4 - Lavezzola Ck.
Temporal Representation: Samples collected between 1/13/2001 and 8/7/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)
QAPP Information Reference(s):
 
 
DECISION ID
92617
Region 5     
Lavezzola Creek (Sierra County)
 
Pollutant: Specific Conductivity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the ninety-four samples exceed the water quality criteria.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of ninety-four samples exceed the water quality criteria and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 92617, Specific Conductivity
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 59376
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 94
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: None of the 94 daily averaged samples exceeded the water quality objective for electrical conductivity in this water body.
Data Reference: Data for Various Pollutants at Placer County Utilities, 2005-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The secondary MCLs for electrical conductivity provide a range of values including a recommended level (900 uS/cm), upper level (1600 uS/cm) and a short-term level (2200 uS/cm). The 'recommended' level of 900 uS/cm was used as it is intended to be protective of all drinking water uses.
Objective/Criterion Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Samples collected at site 4 - Lavezzola Ck.
Temporal Representation: Samples collected between 1/13/2001 and 8/7/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)
QAPP Information Reference(s):
 
 
DECISION ID
92792
Region 5     
Lavezzola Creek (Sierra County)
 
Pollutant: Temperature, water
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the ninety-five samples exceed the evaluation guideline.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of ninety-five samples exceed the evaluation guideline and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 92792, Temperature, water
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 66035
 
Pollutant: Temperature, water
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 95
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: None of the 95 samples exceeded the evaluation guideline for temperature in this water body (SYRCL, 2010).
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The natural receiving water temperature of intrastate waters shall not be altered unless it can be demonstrated to the satisfaction of the Regional Water Board that such alteration in temperature does not adversely affect beneficial uses. In determining compliance with the water quality objectives for temperature, appropriate averaging periods may be applied provided that beneficial uses will be fully protected (Central Valley Regional Board Basin Plan, Pg. III-8.00, Water Quality Objectives).
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: The lethal temperature threshold for Steelhead adult migration and holding and juvenile growth and rearing is 24 degrees Celsius. (Carter, 2008).
Guideline Reference: Effects of Temperature, Dissolved Oxygen/Total Dissolved Gas, Ammonia, and pH on Salmonids. Implications for California's North Coast TMDLs. California Regional Water Quality Control Board, North Coast Region
 
Spatial Representation: Samples were collected at the following location: SYRCL monitoring station 4, Lavezzola Ck
Temporal Representation: Samples were collected monthly from 1/13/2001 to 8/7/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)
QAPP Information Reference(s):
 
 
DECISION ID
92615
Region 5     
Lavezzola Creek (Sierra County)
 
Pollutant: pH
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the ninety-two samples exceed the water quality objective.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of ninety-two samples exceed the water quality objective and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 92615, pH
Region 5     
Lavezzola Creek (Sierra County)
 
LOE ID: 66034
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 92
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: None of the 92 daily averaged samples exceeded the water quality objective for pH in this water body.
Data Reference: Data for Various Pollutants at Placer County Utilities, 2005-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: From the Basin Plan, pH levels should not be lower than 6.5 or higher than 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Samples collected at site 4 - Lavezzola Ck.
Temporal Representation: Samples collected between 1/13/2001 and 8/7/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)