Water Body Name: | Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
Water Body ID: | CAR1151001319990617175806 |
Water Body Type: | River & Stream |
DECISION ID |
103965 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Alkalinity as CaCO3 |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
One lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one sample exceeds the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117776 | ||||
Pollutant: | Alkalinity as CaCO3 | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Alkalinity as CaCO3. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life (Water Quality Control Plan, North Coast Basin). | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
102610 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Aluminum |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3 of the Listing Policy. Under section 3 a single line of evidence are necessary to assess listing status.
One line of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one sample exceeds the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117777 | ||||
Pollutant: | Aluminum | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Aluminum. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The secondary maximum contaminant level listed in Table 64449-A for Aluminum is 0.2 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
100686 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Arsenic |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
Three lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one of the samples exceeded the objective for COLD and MUN and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to SECTION 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117782 | ||||
Pollutant: | Arsenic | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Arsenic. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The maximum contaminant level listed in Table 64431-A for arsenic is 0.010 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 116514 | ||||
Pollutant: | Arsenic | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Arsenic. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The dissolved arsenic criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater for dissolved arsenic is 150 ug/L (California Toxics Rule, 2000). | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
104684 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Benthic Community Effects |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | Benthic Community Effects are being considered for placement on the CWA section 303(d) List under sections 3.9 of the Listing Policy. Under section 3.9, additional lines of evidence (LOEs) associating the Benthic Community Effects decision with a water or sediment concentration of pollutants other than benthic-macroinvertebrate bioassessment or habitat assessment LOEs are necessary to place a water body on the 303(d) List for Benthic Community Effects.
One line of evidence evaluating benthic-macroinvertebrate bioassessment data is available in the administrative record to assess this indicator. The single benthic-macroinvertebrate sample does not exceed the California Stream Condition Index (CSCI) impairment threshold. However, a minimum of two benthic-macroinvertebrate samples are needed to assess listing status. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing Benthic Community Effects in this waterbody segment on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. The single benthic-macroinvertebrate bioassessment sample did not have CSCI scores below 0.79. The available information is insufficient to determine whether the waterbody/pollutant combination should be placed on the 303(d) List of impaired waters at this time. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 96473 | ||||
Pollutant: | Benthic-Macroinvertebrate Bioassessments | ||||
LOE Subgroup: | Population/Community Degradation | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Aquatic Life Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Benthic macroinvertebrate surveys | ||||
Data Used to Assess Water Quality: | The site had a CSCI score(s) of 0.814943731. This score indicates that this site is supporting the aquatic life beneficial use and that the water quality objective has been met. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | From the Water Quality Control Plan, North Coast Region: All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | The California Stream Condition Index (CSCI) is a biological scoring tool that helps aquatic resource managers translate complex data about benthic macroinvertebrates found living in a stream into an overall measure of stream health. The CSCI score is calculated by comparing the expected condition with actual (observed) results (Rhen, A.C. et al., 2015). CSCI scores range from 0 (highly degraded) to greater than 1 (equivalent to reference). CSCI scoring of biological condition are as follows (per the scientific paper supporting the development of the CSCI scoring tool): greater than or equal to 0.92 = likely intact condition, 0.91 to 0.80 = possibly altered condition, 0.79 to 0.63 = likely altered condition, less than or equal to 0.62 = very likely altered condition. Sites with scores below 0.79 are considered to have exceeded the water quality objective for the aquatic life beneficial use. | ||||
Guideline Reference: | Bioassessment in complex environments: designing an index for consistent meaning in different settings | ||||
Spatial Representation: | These samples were collected at the following station: 115SC6093 | ||||
Temporal Representation: | These samples were collected on: 7/7/2011 | ||||
Environmental Conditions: | |||||
QAPP Information: | Data collected following SWAMP QA protocols. QAPP for SWAMP RWB1 Monitoring. | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
101159 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Cadmium |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one sample exceeds the objective for COLD and MUN and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117771 | ||||
Pollutant: | Cadmium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Cadmium. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The maximum contaminant level listed in Table 64431-A for cadmium 0.005 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117769 | ||||
Pollutant: | Cadmium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Cadmium. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
105034 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Chloride |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line(s) of evidence are necessary to assess listing status.
One line of evidence is available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. None of the one samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117772 | ||||
Pollutant: | Chloride | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Chloride. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The secondary maximum contaminant level listed in Table 64449-B for chloride is 250 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
100738 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Chromium |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
One line(s) of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. None of the samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117773 | ||||
Pollutant: | Chromium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Chromium. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The maximum contaminant level listed in Table 64431-A for chromium 0.05 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
100674 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Copper |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one sample exceeded the COLD and MUN beneficial uses and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.4. 4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117774 | ||||
Pollutant: | Copper | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Copper. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 102877 | ||||
Pollutant: | Copper | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Copper. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The secondary maximum contaminant level listed in Table 64449-A copper is 1.0 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
104926 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Lead |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | "This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. None of the one samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met." |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117792 | ||||
Pollutant: | Lead | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Lead. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117780 | ||||
Pollutant: | Lead | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Lead. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for MUN shall not contain concentrations of chemical constituents in excess of values listed in Table 3-2 of the Basin Plan. The value for lead is 0.05 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
103753 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Manganese |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.
One lines of evidence are available in the administrative record to assess this pollutant. The single sample exceeds the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. One of one sample exceeded the objective for MUN and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of one sample is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117751 | ||||
Pollutant: | Manganese | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 1 of 1 samples exceeded the water quality standard for Manganese. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The secondary maximum contaminant level listed in Table 64449-A for Manganese is 0.05 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
100666 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Mercury |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3 of the Listing Policy. Under section 3.11 1 line(s) of evidence are necessary to assess listing status.
Thee lines of evidence are available in the administrative record to assess this pollutant. Zero of one sample exceed the objective for COLD, COM, and MUN beneficial uses. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one samples exceeded the objective for each beneficial use assessed (COLD, COM, MUN) and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 2 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117781 | ||||
Pollutant: | Mercury | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Commercial or recreational collection of fish, shellfish, or organisms | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Mercury. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. The established numeric criteria for mercury to protect of human health from the consumption of organisms only is 0.051 ug/L (California Toxics Rule, 2000). | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117753 | ||||
Pollutant: | Mercury | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Mercury. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. The established numeric criteria for mercury to protect of human health from the consumption of water and organisms is 0.050 ug/L (California Toxics Rule, 2000). | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117752 | ||||
Pollutant: | Mercury | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Mercury. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | National Recommended Water Quality Criteria Continuous Concentrations (4-day average concentrations) for freshwater aquatic organisms exposure to total mercury is 0.77 ug/L. | ||||
Guideline Reference: | National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Current as of 08/03/2016. | ||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
100669 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Nickel |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List
under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status. Three lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one sample exceeds the objective for the COLD, COM and MUN beneficial uses and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117760 | ||||
Pollutant: | Nickel | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Nickel. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117750 | ||||
Pollutant: | Nickel | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Commercial or recreational collection of fish, shellfish, or organisms | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Nickel. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. The established numeric criteria for Nickel to protect human health from consumption of organisms only is 4600 ug/L (California Toxics Rule, 2000). | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117789 | ||||
Pollutant: | Nickel | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Nickel. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The maximum contaminant level listed in Table 64431-A for nickel is 0.1 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
73464 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Nitrogen, Nitrate |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | Do Not List on 303(d) list (TMDL required list)(2016) |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the Section 303(d) List under Section 3.1 of the Listing Policy.
Under Section 3.1, a single line of evidence is necessary to assess listing status. Two lines of evidence are available in the administrative record to assess this pollutant. None of the 168 nitrate samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the Section 303(d) List in the Water Quality Limited Segments category (i.e., sufficient justification to not list). This conclusion is based on the staff findings that: (1) The data used satisfies the data quality requirements of Section 6.1.4 of the Policy. (2) The data used satisfies the data quantity requirements of Section 6.1.5 of the Policy. (3) None of the 168 nitrate samples exceed the water quality objective and this does not exceed the allowable frequency listed in Table 3.1 of the Listing Policy. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 9001 | ||||
Pollutant: | Nitrate | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total Dissolved | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 167 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | None of the 167 nitrate as nitrogen samples collected in Salmon Creek exceeded the objective. The sample concentrations range from non-detect (detection limits of 0.02 mg/L - 0.04 mg/L) to 0.8 mg/L. These samples were collected by the Community Clean Water Institute¿s Volunteer Water Quality Monitoring Program (CCWI 2005, CCWI 2006, CCWI 2007). | ||||
Data Reference: | Community Clean Water Institute Master Data for 2005. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | ||||
Community Clean Water Institute Master Data for 2006. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | |||||
Community Clean Water Institute Master Data for 2004. Downloaded from http://ccwi.org/issues/data.htm on October 1, 2008 | |||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Per the Basin Plan (NCRWQCB 2007): The water quality objective for nitrate as nitrogen is 45 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) - North Coast Region (Region 1) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Samples were collected from six locations in the Salmon Creek Watershed as follows: (1) two sites on the mainstem Salmon Creek from Bittner Road to Salmon Creek School on Bohemian Highway; (2) one site on Tannery Creek off Jennifer Lane and Joy Road; (3) one site on Thurston Creek at Joy Road; (4) one site on Westwood Creek at Bittner Road; and (5) one site on Fay Creek off Fitzpatrick Lane. | ||||
Temporal Representation: | On the mainstem Salmon Creek, samples were collected from January 2004 to August 2006. On Tannery Creek, samples were collected from January 2004 to October 2006. On Thurston Creek, samples were collected from June 2004 to August 2006. On Westwood Creek, samples were collected from January 2004 to August 2006. On Fay Creek, samples were collected from January 2004 to July 2006. | ||||
Environmental Conditions: | There are no known environmental conditions (e.g., seasonality, land use practices, fire events, storms, etc.) that are related to these data. | ||||
QAPP Information: | Samples were collected in accordance with the "Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods" (CCWI 2007). At each site a grab sample was collected using a container on a pole or by a bucket attached to a rope. The samples were then put into sterilized Whirl Pak bags, put into coolers on ice, and brought to the lab for analysis. | ||||
QAPP Information Reference(s): | Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods. Updated April 12, 2007 | ||||
|
|||||
LOE ID: | 117791 | ||||
Pollutant: | Nitrogen, Nitrate | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total Dissolved | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Nitrate as N. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | The California Maximum Contaminant Level for nitrate (NO3 as N) incorporated by reference in the Water Quality Control Plan, North Coast Basin is 10.0 mg/L (Water Quality Control Plan, North Coast Basin). | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
105085 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Nitrogen, Nitrite |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
One line of evidence is available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. None of the one samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 102893 | ||||
Pollutant: | Nitrogen, Nitrite | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Nitrite as N. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The maximum contaminant level listed in Table 64431-A for Nitrite as N is 1.0 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
105062 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Nitrogen, ammonia (Total Ammonia) |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
One line of evidence is available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. None of the one samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117778 | ||||
Pollutant: | Nitrogen, ammonia (Total Ammonia) | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Ammonia as N. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life (North Coast Regional Water Quality Control Board). | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | The USEPA Health Advisory for lifetime exposure to Ammonia as a drinking water level is a concentration of 30 mg/L | ||||
Guideline Reference: | 2012 Edition of the Drinking Water Standards and Health Advisories | ||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
104317 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Selenium |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one sample exceeded the objective for COLD and MUN and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117793 | ||||
Pollutant: | Selenium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Selenium. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): All waters shall be maintained free of toxic substances in concentrations that are toxic to, or that produce detrimental physiological responses in human, plant, animal, or aquatic life. The established numeric selenium criterion continuous concentration (expressed as a 4-day average) to protect aquatic life in freshwater is 5 ug/L (California Toxics Rule, 2000). | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117764 | ||||
Pollutant: | Selenium | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Selenium. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The maximum contaminant level listed in Table 64431-A for selenium is 0.05 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
100688 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Silver |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line(s) of evidence are necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one samples exceeded the objective for COLD and MUN and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117767 | ||||
Pollutant: | Silver | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Silver. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The secondary maximum contaminant level listed in Table 64449-A for silver is 0.1 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117765 | ||||
Pollutant: | Silver | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Silver. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion maximum concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
68274 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Specific Conductivity |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | Do Not List on 303(d) list (TMDL required list)(2016) |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. Zero of 17 samples for COLD exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of 17 samples for COLD exceed the objective and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117754 | ||||
Pollutant: | Specific Conductivity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for SpecificConductivity. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15, Division 4, Article 4, Section 64435 (Tables 2 and 3), and Section 64444.5 (Table 5), and listed in Table 3-2 of this Plan (Water Quality Control Plan, North Coast Basin). | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | California Maximum Contaminant Levels (MCLs) apply to ambient waters under the Basin Plan's \Chemical Constituents\" objective. The California Secondary MCL for specific conductivity is 900 uS/cm." | ||||
Guideline Reference: | California Code of Regulations, Title 22, Division 4, Chapter 15. Domestic Water Quality and Monitoring | ||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 1753 | ||||
Pollutant: | Specific Conductance | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 17 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | There were 17 samples collected (Sandler, et al., 2004). There is no specific conductance water quality objective to evaluate the data and information collected at these two sites. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | The Basin Plan does not have a specific conductance water quality objective for waters within the Bodega HU, Salmon Creek HA. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Sampling was along Salmon Creek only(two locations). One sampling site was in Occidental (SAL060), the other was at the Highway 1 bridge in the town of Bodega Bay (SAL010). | ||||
Temporal Representation: | Samples from the Occidental (SAL060) site were taken once a month, except for October, in 2003. Samples from the Bodega Bay (SAL010) were taken once a month between January and April, and in June and July 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
104675 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Total Dissolved Solids |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.
One lines of evidence are available in the administrative record to assess this pollutant. None of the samples exceed the objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. None of the one samples exceeded the objective and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 26 samples is needed to determine if a beneficial use is fully supported using table 3.2. 4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 117770 | ||||
Pollutant: | Total Dissolved Solids | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Total Dissolved Solids. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15, Division 4, Article 4, Section 64435 (Tables 2 and 3), and Section 64444.5 (Table 5), and listed in Table 3-2 of this Plan (Water Quality Control Plan, North Coast Basin). | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | California Secondary Maximum Contaminant Levels (MCLs) for consumer acceptance objective for total dissolved solids is 500 mg/L. | ||||
Guideline Reference: | California Code of Regulations, Title 22, Division 4, Chapter 15. Domestic Water Quality and Monitoring | ||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
100667 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Zinc |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | New Decision |
Revision Status | Revised |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence are necessary to assess listing status.
Two lines of evidence are available in the administrative record to assess this pollutant. Zero of one sample exceed the objective for COLD and MUN. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that: 1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy. 2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy. 3. Zero of one sample exceeds the objective for the COLD and MUN beneficial uses and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1. 4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 102857 | ||||
Pollutant: | Zinc | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Zinc. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | California Toxics Rule (CTR) lists criterion continuous concentrations to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. | ||||
Objective/Criterion Reference: | Water Quality Standards 2000. Establishment of numeric criteria for priority toxic pollutants for the State of California: Rules and regulations. Federal Register Vol. 65, No. 97. Washington, D.C.: Environmental Protection Agency | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
|
|||||
LOE ID: | 117759 | ||||
Pollutant: | Zinc | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total | ||||
Beneficial Use: | Municipal & Domestic Supply | ||||
Number of Samples: | 1 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Water Board staff assessed SWAMP RWB1 Monitoring data for Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries to determine beneficial use support and results are as follows: 0 of 1 samples exceeded the water quality standard for Zinc. | ||||
Data Reference: | Water Quality Assessment Data for the 2018 solicitation cycle submitted through CEDEN for SWAMP RWB1 Monitoring . | ||||
SWAMP Data: | SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2018): Waters designated for use as domestic or municipal supply (MUN) shall not contain concentrations of chemical constituents in excess of the limits specified in California Code of Regulations, Title 22, Chapter 15. The secondary maximum contaminant level listed in Table 64449-A for Zinc is 5 mg/L. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | The samples were collected at 1 monitoring site(s) (115SC6093) | ||||
Temporal Representation: | The samples were collected between the dates of 2011-07-07 and 2011-07-07 | ||||
Environmental Conditions: | |||||
QAPP Information: | Quality Assurance Program Plan and Standard Operating Procedures for SWAMP program | ||||
QAPP Information Reference(s): | Quality Assurance Program Plans, Quality Assurance Project Plans, and Standard Operating Procedures for the SWAMP program | ||||
DECISION ID |
68348 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Oxygen, Dissolved |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | Do Not List on 303(d) list (TMDL required list)(2016) |
Revision Status | Original |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | Regional Water Board conclusion:
This pollutant was considered for placement on the section 303(d) List in a previous Integrated Report cycle. No new information was reviewed for this current Integrated Report cycle. Therefore, the previous conclusion remains unchanged, and is as follows: This pollutant is being considered for placement on the Section 303(d) List under Section 3.2 of the Listing Policy. Under Section 3.2, a single line of evidence is necessary to assess listing status. Four lines of evidence are available in the administrative record to assess this pollutant. Combined, 13 of the 216 dissolved oxygen samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the Section 303(d) List in the Water Quality Limited Segments category (i.e., sufficient justification to not list). This conclusion is based on the staff findings that: (1) The data used satisfies the data quality requirements of Section 6.1.4 of the Policy. (2) The data used satisfies the data quantity requirements of Section 6.1.5 of the Policy. (3) Thirteen of the 216 dissolved oxygen samples exceed the water quality objective, and this does not exceed the allowable frequency of 36 per the binomial distribution described in Section 3.2 of the Listing Policy. (4) Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 1750 | ||||
Pollutant: | Oxygen, Dissolved | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 10 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Out of the 10 samples taken (Sandler et al., 2004), 2 were below the 6.0 mg/l objective. These were the samples for the month of October and November at 5.2 mg/l and 5.8 mg/l respectively. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: Dissolved oxygen concentrations for waters not listed in Table 3-1, and where dissolved oxygen objectives are not prescribed the dissolved oxygen concentrations shall not be reduced below the following minimum levels at any time; Waters designated COLD - 6.0 mg/l. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | All samples were taken in Fay Creek a tributary to Salmon Creek at 17300 Taylor Rd., Occidental. | ||||
Temporal Representation: | Sampling occurred once a month from January through July, and from October through December in 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1761 | ||||
Pollutant: | Oxygen, Dissolved | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 11 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | One of 11 samples taken, one of the samples June of 2003 was below the 6.0mg/l water quality objective with a value of 5.9 (Sandler, et al., 2004). | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: Dissolved oxygen concentrations for waters not listed in Table 3-1, and where dissolved oxygen objectives are not prescribed the dissolved oxygen concentrations shall not be reduced below the following minimum levels at any time; Waters designated COLD - 6.0 mg/l. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | All samples were taken in Thurston Creek a tributary to Salmon Creek at 16444 Joy Woods Way, Occidental. | ||||
Temporal Representation: | Sampling occurred once a month, January through December 2003, except in November 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1757 | ||||
Pollutant: | Oxygen, Dissolved | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 12 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Of those 12 samples (Sandler, et al., 2004) taken 2 were below the 6.0 mg/l Objective. Samples in June and October had results of 5.5 mg/l and 4.6 mg/l respectively. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: Dissolved oxygen for waters not listed in Table 3-1 and where dissolved oxygen objectives are not prescribed the dissolved oxygen concentrations shall not be reduced below the following minimum levels at any time; Waters designated COLD - 6.0 mg/l. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | All samples were taken in Tannery Creek a tributary to Salmon Creek at Jennifer Lane, at the bridge where the trail starts, Occidental. | ||||
Temporal Representation: | Sampling occurred once a month, January through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 9000 | ||||
Pollutant: | Oxygen, Dissolved | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Aquatic Life Use: | Fish Migration | Fish Spawning | Preservation of Rare & Endangered Species | Warm Freshwater Habitat | Wildlife Habitat | ||||
Number of Samples: | 183 | ||||
Number of Exceedances: | 13 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | Thirteen of the 183 dissolved oxygen samples collected in the Salmon Creek Watershed exceeded the water quality objective. Data were divided into two categories, 1) no spawning, incubation, and emergence occurring and 2) spawning, incubation, and emergence occurring. Presence of salmonid species was determined by the KRIS West Marin-Sonoma web-based information system (KRIS 2008). Information on the timing of spawning, incubation, and emergence for Salmon Creek was not available and thus information from the neighboring Russian River Watershed was used to determine periodicity (Steiner 1996).
The DO values when no spawning, incubation, and emergence were occurring ranged from 3.5 mg/L to 14.1mg/L (3 exceedences of the objective). DO values during times of spawning, incubation, and emergence ranged from 4.5 mg/L to 17.4 mg/L (10 exceedences of the objective). These samples were collected by the Community Clean Water Institute¿s Volunteer Water Quality Monitoring Program (CCWI 2005, CCWI 2006, and CCWI 2007). |
||||
Data Reference: | Community Clean Water Institute Master Data for 2005. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | ||||
Community Clean Water Institute Master Data for 2006. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | |||||
Community Clean Water Institute Master Data for 2004. Downloaded from http://ccwi.org/issues/data.htm on October 1, 2008 | |||||
KRIS West Marin-Sonoma. Hypothesis #1: The distribution and abundance of anadromous salmonids in the KRIS West Marin-Sonoma project area are in decline. Website accessed December 12, 2008. http://www.krisweb.com/kris_wms/krisdb/html/krisweb/analysis/hypoth1_wms.htm | |||||
A History of the Salmonid Decline in the Russian River. | |||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Per the Basin Plan (NCRWQCB 2007): (1) Dissolved oxygen concentrations for waters not listed in Table 3-1, and where dissolved oxygen objectives are not prescribed, shall not be reduced below 6.0 mg/L for waters designated as COLD.
(2) Dissolved oxygen concentrations for waters not listed in Table 3-1, and where dissolved oxygen objectives are not prescribed, shall not be reduced below 9.0 mg/L for waters designated as SPWN during critical spawning and egg incubation periods. |
||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) - North Coast Region (Region 1) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Samples were collected from six locations in the Salmon Creek Watershed as follows: (1) two sites on the mainstem Salmon Creek from Bittner Road to Salmon Creek School on Bohemian Highway; (2) one site on Tannery Creek off Jennifer Lane and Joy Road; (3) one site on Thurston Creek at Joy Road; (4) one site on Westwood Creek at Bittner Road; and (5) one site on Fay Creek off Fitzpatrick Lane. | ||||
Temporal Representation: | On the mainstem Salmon Creek, samples were collected during 68 site visits from January 2004 to December 2006. On Tannery Creek, samples were collected during 34 site visits from January 2004 to November 2006. On Thurston Creek, samples were collected during 32 site visits from January 2004 to December 2006. On Westwood Creek, samples were collected during 36 site visits from January 2004 to December 2006. On Fay Creek, samples were collected during 30 site visits from January 2004 to November 2006. The DO samples were collected as instantaneous measurements and do not represent diurnal conditions. | ||||
Environmental Conditions: | There are no known environmental conditions (e.g., seasonality, land use practices, fire events, storms, etc.) that are related to these data. | ||||
QAPP Information: | Samples were collected in accordance with the "Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods" (CCWI 2007). | ||||
QAPP Information Reference(s): | Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods. Updated April 12, 2007 | ||||
DECISION ID |
73912 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Phosphorus |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | Do Not List on 303(d) list (TMDL required list)(2016) |
Revision Status | Original |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | Regional Water Board conclusion: This pollutant was considered for placement on the section 303(d) List in a previous Integrated Report cycle. No new information was reviewed for this current Integrated Report cycle. Therefore, the previous conclusion remains unchanged, and is as follows:
This pollutant is being considered for placement on the Section 303(d) List under Section 3.1 of the Listing Policy. Under Section 3.1 a single line of evidence is necessary to assess listing status. Five lines of evidence are available in the administrative record to assess this pollutant. It is unknown if any of the phosphorus samples exceed the water quality objective as there is insufficient information available to determine exceedance. Specifically, the samples cannot be compared to the objective because diel samples for dissolved oxygen (DO), pH, and/or chlorophyll-a are not available. Nutrients such as phosphorus do not impair beneficial uses by themselves, or cause non-attainment of the objective. Rather, they cause indirect impacts through algal growth and extreme diel patterns for DO and pH, which then impair uses. Waterbody-specific factors such as riparian cover, flow conditions, and stream channel configuration also affect how nutrients are processed within the stream and play a large role in determining whether or not nuisance algal conditions will prevail. For these reasons, comparing a single nutrient value to the biostimulatory objective is not recommended. Instead, nutrient-related indicator parameters, such as diel measurements of DO, pH, and/or chlorophyll-a, should be evaluated to determine attainment of the objective and protection of beneficial uses. When nutrient-related indicator parameters exceed targets, nutrient concentrations will then be analyzed to determine whether phosphorus should be added to a possible listing under the 303(d) List. Therefore, the weight of evidence indicates that there is insufficient information available to determine if it is appropriate to place this water segment-pollutant combination on the Section 303(d) List in the Water Quality Limited Segments category. This conclusion is also based on the staff findings that: (1) The data used satisfies the data quality requirements of Section 6.1.4 of the Policy. (2) The data used satisfies the data quantity requirements of Section 6.1.5 of the Policy. (3) Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. Note: Lines of evidence for both orthophosphate and total dissolved phosphorus data support this Decision. Total dissolved phosphorus includes orthophosphate. Phosphorus is used as the pollutant for this Decision because it includes both fractions and is easier to understand its relationship to other nutrients and the water quality objective. |
Regional Board Decision Recommendation: | This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board. |
|
|||||
LOE ID: | 9043 | ||||
Pollutant: | Phosphorus | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | Total Dissolved | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Aquatic Life Use: | Fish Migration | Fish Spawning | Preservation of Rare & Endangered Species | Warm Freshwater Habitat | Wildlife Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | It is unknown whether any of the 171 phosphorus samples collected in the Salmon Creek Watershed exceed the objective as there is insufficient information available to determine exceedance. Specifically, the samples cannot be compared to the objective because diel samples for dissolved oxygen (DO), pH, and/or chlorophyll-a are not available. Nutrients, such as phosphorus, alone do not impair beneficial uses or cause non-attainment of the objective. Rather, they cause indirect impacts through algal growth and extreme diel patterns for DO and pH, which then impair uses. Waterbody-specific factors such as riparian cover, flow conditions, and stream channel configuration also affect how nutrients are processed within the stream and play a large role in determining whether or not nuisance algal conditions will prevail. For these reasons, comparing a single nutrient value to the biostimulatory objective is not recommended. Instead, nutrient-related indicator parameters, such as diel measurements of DO, pH, and/or chlorophyll-a, should be evaluated to determine attainment of the objective and protection of beneficial uses. When nutrient-related indicator parameters exceed targets, nutrient concentrations will then be analyzed to determine whether phosphorus should be added to a possible listing under the 303(d) List. The sample concentrations range from non-detect (reporting limits of 0.03 mg/L and 0.1 mg/L) to 0.17 mg/L. These samples were collected by the Community Clean Water Institute¿s Volunteer Water Quality Monitoring Program (CCWI 2005, CCWI 2006, and CCWI 2007). | ||||
Data Reference: | Community Clean Water Institute Master Data for 2005. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | ||||
Community Clean Water Institute Master Data for 2006. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | |||||
Community Clean Water Institute Master Data for 2004. Downloaded from http://ccwi.org/issues/data.htm on October 1, 2008 | |||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Per the Basin Plan (NCRWQCB 2007): Waters shall not contain biostimulatory substances in concentrations that promote aquatic growths to the extent that such growths cause nuisance or adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) - North Coast Region (Region 1) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Samples were collected from six locations in the Salmon Creek Watershed as follows: (1) two sites on the mainstem Salmon Creek from Bittner Road to Salmon Creek School on Bohemian Highway; (2) one site on Tannery Creek off Jennifer Lane and Joy Road; (3) one site on Thurston Creek at Joy Road; (4) one site on Westwood Creek at Bittner Road; and (5) one site on Fay Creek off Fitzpatrick Lane. | ||||
Temporal Representation: | On the mainstem Salmon Creek, samples were collected from January 2004 to August 2006. On Tannery Creek, samples were collected from January 2004 to October 2006. On Thurston Creek, samples were collected from January 2004 to July 2006. On Westwood Creek, samples were collected from January 2004 to August 2006. On Fay Creek, samples were collected from January 2004 to July 2006. | ||||
Environmental Conditions: | There are no known environmental conditions (e.g., seasonality, land use practices, fire events, storms, etc.) that are related to these data. | ||||
QAPP Information: | Samples were collected in accordance with the "Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods" (CCWI 2007). | ||||
QAPP Information Reference(s): | Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods. Updated April 12, 2007 | ||||
|
|||||
LOE ID: | 1751 | ||||
Pollutant: | Phosphate | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | In Fay Creek, a tributary of Salmon Creek, orthophosphate concentrations ranged from non-dectable to 0.065. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | The Basin Plan does not have a water quality objective for orthophosphate. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | There is no appropriate interpretive evaluation guideline for orthophosphate. | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | All samples were taken in Fay Creek a tributary to Salmon Creek at 17300 Taylor Rd., Occidental. | ||||
Temporal Representation: | Sampling occurred once a month from January through July, and from October through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1760 | ||||
Pollutant: | Phosphate | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | The 12 samples from the Tannery Creek sampling site ranged from non-detect to 0.130 mg/l (Sandler, et al., 2004). | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | The Basin Plan does not have a water quality objective for orthophosphate. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | There is no appropriate interpretive evaluation guideline for orthophosphate. | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | Sampling was taken on Tannery Creek (at Jennifer Lane and the bridge where the trail starts, Occidental), a tributary of Salmon Creek. | ||||
Temporal Representation: | Samples were taken once a month from January through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1752 | ||||
Pollutant: | Phosphate | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | The 11 samples from the Salmon Creek at Occidental sampling site ranged from non-detect to 0.082 mg/l. The 6 samples from the Salmon Creek at Bodega Bay sampling site ranged from 0.016 to 0.130 mg/l (Sandler, et al., 2004). | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | The Basin Plan does not have a water quality objective for orthophosphate. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | There is no appropriate interpretive evaluation guideline for orthophosphate. | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | Sampling was along Salmon Creek only (two locations). One sampling site was in Occidental (SAL060), the other was at the Highway 1 bridge in the town of Bodega Bay (SAL010). | ||||
Temporal Representation: | Samples from the Occidental (SAL060) site were taken monthly, except for October, in 2003. Samples from the Bodega Bay (SAL010) were taken monthly between January and April, and in June and July 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1762 | ||||
Pollutant: | Phosphate | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 12 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | The 12 samples from the Westwood Creek sampling site ranged from non-detect to 0.082 mg/l. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | The Basin Plan does not have a water quality objective for orthophosphate. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | There is no appropriate interpretive evaluation guideline for orthophosphate. | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | Sampling was limited to Westwood Creek a tributary to Salmon Creek. | ||||
Temporal Representation: | Samples were taken monthly from January through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
68387 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | Turbidity |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | Do Not List on 303(d) list (TMDL required list)(2016) |
Revision Status | Original |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | Regional Board Conclusion:
The pollutant was considered for placement on the section 303(d) list in a previous assessment cycle. No new information was reviewed for this current assessment cycle. Therefore, the previous conclusion remains unchanged, and is as follows: This pollutant is being considered for placement on the Section 303(d) List under Section 3.2 of the Listing Policy. Under Section 3.2 a single line of evidence is necessary to assess listing status. Four lines of evidence are available in the administrative record to assess turbidity for Bodega HU, Salmon Creek HA. It should be noted that data from four additional LOEs (1763, 1749, 1756, and 1759) are re-evaluated in LOEs 31543, 31541, and 31544 respectively. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the section 303(d) list in the Water Quality Limited Segments category (i.e., sufficient justification to not list). This conclusion is based on the staff findings that: (1) The data used satisfies the data quality requirements of Section 6.1.4 of the Policy. (2) The data used satisfies the data quantity requirements of Section 6.1.5 of the Policy. (3) At the present time, natural background turbidity levels have not been determined for this water body, and exceedence probabilities (the turbidity levels, associated with flow, that are exceeded X% of the time) have not been calculated. Thus, there is currently no appropriate evaluation guideline for this water body, and no way to determine whether the objective is being exceeded. (4) Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 1755 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Visual | ||||
Matrix: | Not Specified | ||||
Fraction: | |||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Pictures were submitted for Salmon Creek from USEPA solicitation of information. There were 8 photographs taken on January 11, 2004. The photographs presented show streambank conditions in the Salmon Creek watershed observed on January 11, 2004. Pictures #1 through #6 show the Salmon Creek as viewed from the Bodega Hwy at the bridge over Salmon Creek, just west of the Valley Ford Cut-off Road. Pictures #1 through #4 show stream banks and upland pastureland on the north side of the road where the stream flows westward (from right to left in this picture) from the town of Freestone. Pictures #7 and #8 show the view of Salmon Creek as it flows from the Bodega Hwy Bridge westward to the town of Bodega. (North Coast RWQCB, 2004b) | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: The suspended sediment load and suspended sediment discharge rate of surface waters shall not be altered in such a manner as to cause nuisance or adversely affect beneficial uses. Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. Water shall not contain substances in concentrations that result in deposition of material that causes nuisance or adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | |||||
Temporal Representation: | |||||
Environmental Conditions: | |||||
QAPP Information: | None provided. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 31543 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 12 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | At the present time, natural background turbidity levels have not been determined for this watershed, and exceedence probabilities (the turbidity, associated with flow, that is exceeded X% of the time) have not been calculated. Thus, there is currently no appropriate evaluation guideline for this watershed, and no way to determine whether the objective is being exceeded. This LOE replaces LOE 1763 which utilized an evaluation guideline that was determined to be inappropriate by the Intagrated Report Roundtable comprised of State and Regional Water Board staff members. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2011): Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | All samples were taken in Westwood Creek a tributary to Salmon Creek at Westwood Lane and Bittner Rd., Occidental. | ||||
Temporal Representation: | Sampling occurred once a month from January through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | Placeholder reference 2006 303(d) | ||||
|
|||||
LOE ID: | 1759 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Sediment | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 11 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | There were 11 samples taken and all of the samples were well below the evaluation guideline, none of the samples were in exceedance. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: The suspended sediment load and suspended sediment discharge rate of surface waters shall not be altered in such a manner as to cause nuisance or adversely affect beneficial uses. Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. Water shall not contain substances in concentrations that result in deposition of material that causes nuisance or adversely affect beneficial uses | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | The evaluation guideline that has been used to determine turbidity exceedance is from published-peer reviewed paper, "The Effects of Chronic Turbidity on Density and Growth of Steelheads and Coho Salmon", John W Sigler (1984). The guideline is "In our studies, as little as 25 NTUs of turbidity caused a reduction in fish growth." | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | Sampling was along Thurston Creek, a tributary of Salmon Creek. Samples were taken at 16444 Joy Woods Way, Occidental. | ||||
Temporal Representation: | Samples were taken monthly from January through December 2003, except in November 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1763 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Sediment | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 12 | ||||
Number of Exceedances: | 1 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | There were 12 samples taken , one of the samples was in exceedance of the evaluation guideline. This sample was taken in February at 42.4 NTU. The other samples were all well below the evaluation guideline. (Sandler, et al., 2004) | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: The suspended sediment load and suspended sediment discharge rate of surface waters shall not be altered in such a manner as to cause nuisance or adversely affect beneficial uses. Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. Water shall not contain substances in concentrations that result in deposition of material that causes nuisance or adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | The evaluation guideline that has been used to determine turbidity exceedance is from published-peer reviewed paper, "The Effects of Chronic Turbidity on Density and Growth of Steelheads and Coho Salmon", John W Sigler (1984). The guideline is "In our studies, as little as 25 NTUs of turbidity caused a reduction in fish growth." | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | All samples were taken in Westwood Creek a tributary to Salmon Creek at Westwood Lane and Bittner Rd., Occidental. | ||||
Temporal Representation: | Sampling occurred once a month from January through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1756 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Sediment | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 17 | ||||
Number of Exceedances: | 2 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | There were 6 turbidity samples taken from the Bodega Bay site and 11 samples taken at Occidental site. There was one sample in exceedance of the guideline at 38.4 NTU out of 6 samples from Bodega Bay site. There was one sample in exceedance of the guideline at the Occidental site out of 11 samples. Taken together there were 2 out of 17 samples that exceeded the water quality objective/criterion. (Sandler, et al., 2004) | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: The suspended sediment load and suspended sediment discharge rate of surface waters shall not be altered in such a manner as to cause nuisance or adversely affect beneficial uses. Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. Water shall not contain substances in concentrations that result in deposition of material that causes nuisance or adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | The evaluation guideline that has been used to determine turbidity exceedance is from published-peer reviewed paper, "The Effects of Chronic Turbidity on Density and Growth of Steelheads and Coho Salmon", John W Sigler (1984). The guideline is "In our studies, as little as 25 NTUs of turbidity caused a reduction in fish growth." | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | Sampling was along Salmon Creek only. One sampling site was in Occidental (SAL060), the other was at the Highway 1 bridge in the town of Bodega Bay (SAL010). | ||||
Temporal Representation: | Samples from the Occidental (SAL060) site were taken once a month, except for October, in 2003. Samples from the Bodega Bay (SAL010) were taken once a month between January and April, and in June and July 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 1749 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 10 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | There were 10 samples taken and all of the samples were well below the evaluation guideline, none of the samples were in exceedance (Sandler, et al., 2004). | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: The suspended sediment load and suspended sediment discharge rate of surface waters shall not be altered in such a manner as to cause nuisance or adversely affect beneficial uses. Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. Water shall not contain substances in concentrations that result in deposition of material that causes nuisance or adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | The evaluation guideline that has been used to determine turbidity exceedance is from published-peer reviewed paper, "The Effects of Chronic Turbidity on Density and Growth of Steelheads and Coho Salmon", John W Sigler (1984). The guideline is "In our studies, as little as 25 NTUs of turbidity caused a reduction in fish growth." | ||||
Guideline Reference: | Placeholder reference 2006 303(d) | ||||
Spatial Representation: | All samples were taken in Fay Creek a tributary to Salmon Creek at 17300 Taylor Rd., Occidental. | ||||
Temporal Representation: | Sampling occurred once a month from January through July, and from October through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | |||||
|
|||||
LOE ID: | 31541 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 17 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | At the present time, natural background turbidity levels have not been determined for this watershed, and exceedence probabilities (the turbidity, associated with flow, that is exceeded X% of the time) have not been calculated. Thus, there is currently no appropriate evaluation guideline for this watershed, and no way to determine whether the objective is being exceeded. This LOE replaces LOE 1756 which utilized an evaluation guideline that was determined to be inappropriate by the Intagrated Report Roundtable comprised of State and Regional Water Board staff members. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2011): Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Sampling was along Salmon Creek only. One sampling site was in Occidental (SAL060), the other was at the Highway 1 bridge in the town of Bodega Bay (SAL010). | ||||
Temporal Representation: | Samples from the Occidental (SAL060) site were taken once a month, except for October, in 2003. Samples from the Bodega Bay (SAL010) were taken once a month between January and April, and in June and July 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | Placeholder reference 2006 303(d) | ||||
|
|||||
LOE ID: | 31544 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 11 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | At the present time, natural background turbidity levels have not been determined for this watershed, and exceedence probabilities (the turbidity, associated with flow, that is exceeded X% of the time) have not been calculated. Thus, there is currently no appropriate evaluation guideline for this watershed, and no way to determine whether the objective is being exceeded. This LOE replaces LOE 1759 which utilized an evaluation guideline that was determined to be inappropriate by the Intagrated Report Roundtable comprised of State and Regional Water Board staff members. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2011): Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Sampling was along Thurston Creek, a tributary of Salmon Creek. Samples were taken at 16444 Joy Woods Way, Occidental. | ||||
Temporal Representation: | Samples were taken monthly from January through December 2003, except in November 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | Placeholder reference 2006 303(d) | ||||
|
|||||
LOE ID: | 31542 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 10 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | At the present time, natural background turbidity levels have not been determined for this watershed, and exceedence probabilities (the turbidity, associated with flow, that is exceeded X% of the time) have not been calculated. Thus, there is currently no appropriate evaluation guideline for this watershed, and no way to determine whether the objective is being exceeded. This LOE replaces LOE 1749 which utilized an evaluation guideline that was determined to be inappropriate by the Intagrated Report Roundtable comprised of State and Regional Water Board staff members. | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Water Quality Control Plan, North Coast Region (NCRWQCB 2011): Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) for the North Coast Region | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | All samples were taken in Fay Creek a tributary to Salmon Creek at 17300 Taylor Rd., Occidental. | ||||
Temporal Representation: | Sampling occurred once a month from January through July, and from October through December 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||
QAPP Information Reference(s): | Placeholder reference 2006 303(d) | ||||
|
|||||
LOE ID: | 1758 | ||||
Pollutant: | Turbidity | ||||
LOE Subgroup: | Visual | ||||
Matrix: | Not Specified | ||||
Fraction: | |||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 0 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Pictures were submitted for Salmon Creek from USEPA solicitation of information. There were 6 photographs taken on January 11, 2004. This memo includes photo documentation of riparian conditions observed on Nolan Creek on January 11, 2004. Nolan Creek flows southward from Joy Ridge where it joins Thurston Creek before passing under the Bodega Hwy about 1000 feet west of Joy Road near the town of Bodega. Nolan Creek passes southward under the Bodega Hwy bridge where it joins Salmon Creek about 2000 feet south of the highway. The photographs below were taken from the Bodega Hwy at or near the Nolan Creek Bridge.
Picture 1 below shows Nolan Creek flowing away to the south toward Salmon Creek. Picture 2 above looks upstream at the pastoral landscape north of Bodega Hwy at Joy Road. Picture 3 and Picture 4 below show examples of the cattle trails and trampled, denuded stream banks that appear to provide sources of fine sediment to the tributary streams and main stem of Salmon Creek. Pictures 5 and Picture 6 below illustrate fine sediment delivery to the creeks from trampled stream banks. (North Coast RWQCB, 2004b) |
||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: The suspended sediment load and suspended sediment discharge rate of surface waters shall not be altered in such a manner as to cause nuisance or adversely affect beneficial uses. Turbidity shall not be increased more than 20 percent above naturally occurring background levels. Allowable zones of dilution within which higher percentages can be tolerated may be defined for specific discharges upon the issuance of discharge permits or waiver thereof. Water shall not contain substances in concentrations that result in deposition of material that causes nuisance or adversely affect beneficial uses. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | |||||
Temporal Representation: | |||||
Environmental Conditions: | |||||
QAPP Information: | None provided. | ||||
QAPP Information Reference(s): | |||||
DECISION ID |
68386 |
Region 1 |
Bodega HU, Salmon Creek HA, Salmon Creek and its tributaries |
||
Pollutant: | pH |
Final Listing Decision: | Do Not List on 303(d) list (TMDL required list) |
Last Listing Cycle's Final Listing Decision: | Do Not List on 303(d) list (TMDL required list)(2016) |
Revision Status | Original |
Impairment from Pollutant or Pollution: | Pollutant |
Regional Board Conclusion: | Regional Board Conclusion:
The pollutant was considered for placement on the section 303(d) list in a previous assessment cycle. No new information was reviewed for this current assessment cycle. Therefore, the previous conclusion remains unchanged, and is as follows: Regional Water Board conclusion: This pollutant was considered for placement on the section 303 (d) list in a previous Integrated Report cycle. No new information was reviewed for this current Integrated Report cycle. Therefore, the previous conclusion remains unchanged, and is as follows: This pollutant is being considered for placement on the Section 303(d) List under Section 3.2 of the Listing Policy. Under Section 3.2, a single line of evidence is necessary to assess listing status. Two lines of evidence are available in the administrative record to assess this pollutant. Combined, 2 of 211 pH samples exceed the water quality objective. Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the Section 303(d) List in the Water Quality Limited Segments category (i.e., sufficient justification to not list). This conclusion is based on the staff findings that: (1) The data used satisfies the data quality requirements of Section 6.1.4 of the Policy. (2) The data used satisfies the data quantity requirements of Section 6.1.5 of the Policy. (3) Two of the 211 pH samples exceed the water quality objective, and this does not exceed the allowable frequency of 35 per the binomial distribution described in Section 3.2 of the Listing Policy. (4) Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met. |
Regional Board Decision Recommendation: | This is a decision previously approved by the State Water Resources Control Board and the USEPA. No new data were assessed by the Regional Board for the current cycle. The decision has not changed. |
State Board Review of Regional Board Conclusion and Recommendation: | |
State Board Decision Recommendation: | |
|
|||||
LOE ID: | 8999 | ||||
Pollutant: | pH | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Aquatic Life Use: | Fish Migration | Fish Spawning | Preservation of Rare & Endangered Species | Warm Freshwater Habitat | Wildlife Habitat | ||||
Number of Samples: | 200 | ||||
Number of Exceedances: | 0 | ||||
Data and Information Type: | PHYSICAL/CHEMICAL MONITORING | ||||
Data Used to Assess Water Quality: | None of the 200 samples for pH collected in the Salmon Creek Watershed exceeded the pH water quality objective. The pH values ranged from 6.5 to 8.5. These samples were collected by the Community Clean Water Institute¿s Volunteer Water Quality Monitoring Program (CCWI 2005, CCWI 2006, CCWI 2007). | ||||
Data Reference: | Community Clean Water Institute Master Data for 2005. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | ||||
Community Clean Water Institute Master Data for 2006. Downloaded from http://ccwi.org/issues/data.htm on August 25, 2008 | |||||
Community Clean Water Institute Master Data for 2004. Downloaded from http://ccwi.org/issues/data.htm on October 1, 2008 | |||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Per the Basin Plan (NCRWQCB 2007): The maximum pH objective is 8.5. The minimum pH objective is 6.5. | ||||
Objective/Criterion Reference: | Water Quality Control Plan (Basin Plan) - North Coast Region (Region 1) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Samples were collected from six locations in the Salmon Creek Watershed as follows: (1) two sites on the mainstem Salmon Creek from Bittner Road to Salmon Creek School on Bohemian Highway; (2) one site on Tannery Creek off Jennifer Lane and Joy Road; (3) one site on Thurston Creek at Joy Road; (4) one site on Westwood Creek at Bittner Road; and (5) one site on Fay Creek off Fitzpatrick Lane. | ||||
Temporal Representation: | On the mainstem Salmon Creek, samples were collected during 68 site visits from January 2004 to December 2006. On Tannery Creek, samples were collected during 34 site visits from January 2004 to November 2006. On Thurston Creek, samples were collected during 32 site visits from January 2004 to December 2006. On Westwood Creek, samples were collected during 36 site visits from January 2004 to December 2006. On Fay Creek, samples were collected during 30 site visits from January 2004 to November 2006. The pH samples were collected as instantaneous measurements and do not represent diurnal conditions. | ||||
Environmental Conditions: | There are no known environmental conditions (e.g., seasonality, land use practices, fire events, storms, etc.) that are related to these data. | ||||
QAPP Information: | Samples were collected in accordance with the "Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods" (CCWI 2007). | ||||
QAPP Information Reference(s): | Community Clean Water Institute Volunteer Water Quality Monitoring Program Sampling and Analysis Methods. Updated April 12, 2007 | ||||
|
|||||
LOE ID: | 1754 | ||||
Pollutant: | pH | ||||
LOE Subgroup: | Pollutant-Water | ||||
Matrix: | Water | ||||
Fraction: | None | ||||
Beneficial Use: | Cold Freshwater Habitat | ||||
Number of Samples: | 11 | ||||
Number of Exceedances: | 2 | ||||
Data and Information Type: | Not Specified | ||||
Data Used to Assess Water Quality: | Eleven of 11 samples from the Occidental sampling site were within the 6.5-8.5 range. The samples from the other site, Salmon Creek at Bodega Bay, 2 of the 6 samples exceeded the objective. The two samples at this site that exceeded the objective were at 8.6 and 9.1. (Sandler, et al., 2004) | ||||
Data Reference: | Placeholder reference 2006 303(d) | ||||
SWAMP Data: | Non-SWAMP | ||||
Water Quality Objective/Criterion: | Basin Plan: pH shall not be depressed below 6.5 nor raised above 8.5, and that changes in the normal ambient pH shall not exceed 0.5 units within the above range in freshwaters designated COLD or WARM. | ||||
Objective/Criterion Reference: | Placeholder reference 2006 303(d) | ||||
Evaluation Guideline: | |||||
Guideline Reference: | |||||
Spatial Representation: | Sampling was along Salmon Creek only (two locations). One sampling site was in Occidental (SAL060), the other was at the Highway 1 bridge in the town of Bodega Bay (SAL010). | ||||
Temporal Representation: | Eleven samples from the Occidental site (SAL060) site were taken monthly, except for October, in 2003. Six samples from the Bodega Bay site (SAL010) were taken monthly between January and April, and in June and July 2003. | ||||
Environmental Conditions: | |||||
QAPP Information: | Draft QAPP for Volunteer Water Quality Monitoring Project for the Community Clean Water Institute. | ||||