Welcome to the State Water Resources Control Board Welcome to the California Environmental Protection Agency
UST Program - LG 113 - Continuous Interstitial Pipeline Monitoring Method (Liquid Filled)

UST Program - LG 113 - Continuous Interstitial Pipeline Monitoring Method (Liquid Filled)


Revision Date: October 19, 2007

Continuous Interstitial Monitoring Method
(Liquid Filled)

Click on the vendors specific Equipment Name to go to that Listing.

VENDOR
EQUIPMENT NAME
LEAK RATE/THRESHOLD /MAX TANK OR MAX PIPELINE LENGTH*
Ameron International Dualoy 3000/LCX and MCX Pipe Monitoring System Brine Filled Interstitial Space Brine solutions is used to fill the Ameron Dualoy 3000/LCX and MCX fiberglass double-wall pipe interstice. A reservoir at the high point of the system contains a dual-point level sensor that will alarm if the liquid level is too high or too low./344 feet
Dualoy 3000/LCX and MCX Pipe Monitoring System Brine Filled Pressurized Interstitial Space Brine solution is used to fill the Ameron Dualoy 3000/LCX and MCX fiberglass double-wall pipe interstice, which is pressurized using an air compressor or gas bottle. A reservoir contains a dual-point level sensor that will alarm if the liquid level is too high or too low./344 feet
Containment Solutions, Inc. (originally listed as Fluid Containment and O/C Tanks) FCI Liquid Filled Interstitial Monitor
Tank Model DWT6 with Model FHRB 810 Level Sensor
A Fluid reservoir is attached to the top of the tank and is open to the interstice through the bottom and is normally filled with a brine solution in freeze areas or water in non-freeze areas. The reservoir is equipped with a dual-point level sensor to provide for low level and high level alarms./For use with all Containment Solution tank sizes.
Western Fiberglass, Inc. Co-Flow Hydraulic Interstitial Monitoring System Propylene glycol is used to fill the Western Fiberglass, Inc., double-walled/coaxial flexible pipeline interstice. Two reservoirs are used to contain the liquid, one at each end of the system./200feet
Co-Flow Hydraulic Interstitial Monitoring System
Propylene Glycol Filled Pressurized Interstitial Space
Propylene glycol is used to fill the Western Fiberglass, Inc., double-walled/coaxial flexible pipe interstice. A pressurized cylinder is used to maintain pressure in the reservoir./200 feet
Liquid-Filled Reservoir for Double-Wall Sumps with Liquid Sensor Models WF-3 and WF-750
Propylene glycol is used to fill the Western Fiberglass double-walled sump or under dispenser containment sump interstice./Not applicable.
Xerxes Corp. Xerxes Trucheck Continuous Leak Detection System A Fluid reservoir is attached to the top of the tank and is open to the interstice through the bottom and is filled with a brine solution. The reservoir is equipped with an electronic probe to provide for low level and high level alarms./For use with all Xerxes tank sizes.