Welcome to the State Water Resources Control Board Welcome to the California Environmental Protection Agency
Governor's Website Visit the Water Board Members Page
Agendas
My Water Quality
Performance Report
UST Program - LG 113 - Continuous Interstitial Pipeline Monitoring Method (Liquid Filled)

UST Program - LG 113 - Continuous Interstitial Monitoring Method (Liquid Filled)


Revision Date: October 19, 2007

Continuous Interstitial Monitoring Method
(Liquid Filled)

Click on the vendors specific Equipment Name to go to that Listing.

VENDOR
EQUIPMENT NAME
LEAK RATE/THRESHOLD /MAX TANK OR MAX PIPELINE LENGTH*
Ameron International Dualoy 3000/LCX and MCX Pipe Monitoring System Brine Filled Interstitial Space Brine solutions is used to fill the Ameron Dualoy 3000/LCX and MCX fiberglass double-wall pipe interstice. A reservoir at the high point of the system contains a dual-point level sensor that will alarm if the liquid level is too high or too low./344 feet
Dualoy 3000/LCX and MCX Pipe Monitoring System Brine Filled Pressurized Interstitial Space Brine solution is used to fill the Ameron Dualoy 3000/LCX and MCX fiberglass double-wall pipe interstice, which is pressurized using an air compressor or gas bottle. A reservoir contains a dual-point level sensor that will alarm if the liquid level is too high or too low./344 feet
Containment Solutions, Inc. (originally listed as Fluid Containment and O/C Tanks) FCI Liquid Filled Interstitial Monitor
Tank Model DWT6 with Model FHRB 810 Level Sensor
A Fluid reservoir is attached to the top of the tank and is open to the interstice through the bottom and is normally filled with a brine solution in freeze areas or water in non-freeze areas. The reservoir is equipped with a dual-point level sensor to provide for low level and high level alarms./For use with all Containment Solution tank sizes.
Western Fiberglass, Inc. Co-Flow Hydraulic Interstitial Monitoring System Propylene glycol is used to fill the Western Fiberglass, Inc., double-walled/coaxial flexible pipeline interstice. Two reservoirs are used to contain the liquid, one at each end of the system./200feet
Co-Flow Hydraulic Interstitial Monitoring System
Propylene Glycol Filled Pressurized Interstitial Space
Propylene glycol is used to fill the Western Fiberglass, Inc., double-walled/coaxial flexible pipe interstice. A pressurized cylinder is used to maintain pressure in the reservoir./200 feet
Liquid-Filled Reservoir for Double-Wall Sumps with Liquid Sensor Models WF-3 and WF-750
Propylene glycol is used to fill the Western Fiberglass double-walled sump or under dispenser containment sump interstice./Not applicable.
Xerxes Corp. Xerxes Trucheck Continuous Leak Detection System A Fluid reservoir is attached to the top of the tank and is open to the interstice through the bottom and is filled with a brine solution. The reservoir is equipped with an electronic probe to provide for low level and high level alarms./For use with all Xerxes tank sizes.
 
 

.