Pollutant: Indicator Bacteria
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of the 86 samples analyzed for E. coli exceed the 235/100 ml. USEPA Ambient Water Quality Criteria for Bacteria (1986) of 235 MPN/100 ml for REC-1, and 0 of 84 samples analyzed for total coliform exceed the Guidance for Fresh Water Beaches (CDPH, 2006) criteria of 10,000 MPN/100ml for REC-1.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of the 86 samples analyzed for E. coli exceed the 235/100 ml. USEPA Ambient Water Quality Criteria for Bacteria (1986) of 235 MPN/100 ml for REC-1, and 0 of 84 samples analyzed for total coliform exceed the Guidance for Fresh Water Beaches (CDPH, 2006) criteria of 10,000 MPN/100ml for REC-1 and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 95519, Indicator Bacteria
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 72661
 
Pollutant: Escherichia coli (E. coli)
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Water Contact Recreation
 
Number of Samples: 86
Number of Exceedances: 0
 
Data and Information Type: Not Specified
Data Used to Assess Water Quality: Zero of the 86 samples exceeded the E. coli objective.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses. (Water Quality Control Plan, Central Valley Region, Sacramento River and San Joaquin River Basins)
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: The E. coli concentration shall not exceed more than 235/100 ml. USEPA Ambient Water Quality Criteria for Bacteria - 1986.
Guideline Reference: Ambient Water Quality Criteria for Bacteria - 1986. EPA440/5-84-002
 
Spatial Representation: The samples were collected at SYRCL monitoring station 10 Indian springs, station 28 Hampshire Rocks, station 38 Plavada, station 39 Van Norden Dam, station 43 Rainbow Bend, and station 44 Kingvale. WBID: CAR5173401020110207094836
Temporal Representation: The samples were collected approximately monthly between 2001 and 2007.
Environmental Conditions:
QAPP Information: This data was collected under the Water Monitoring Quality Assurance Project Plan for the Yuba Watershed Council Monitoring Committee. Rev 1.3. qa12
QAPP Information Reference(s):
 
 
DECISION ID
93804
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: Iron
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1, a single line of evidence is necessary to assess listing status.

Two lines of evidence are available in the administrative record to assess this pollutant. Zero of eighteen samples exceed the evaluation guideline for COLD.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List in the Water Quality Limited Segments category.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of eighteen samples exceed the evaluation guideline for COLD and this does not exceed the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 93804, Iron
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 72683
 
Pollutant: Iron
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 9
Number of Exceedances: 0
 
Data and Information Type: Non-fixed station physical/chemical (conventional + toxicants)
Data Used to Assess Water Quality: None of the nine samples exceeded the evaluation guideline of 1,000 ug/L.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: National Recommended Water Quality Criteria Continuous Concentrations are intended protect freshwater aquatic organisms from chronic exposures and are expressed as 4-day average concentrations. The evaluation guideline for iron is 1,000 ug/L.
Guideline Reference: National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology
 
Spatial Representation: Samples were collected from station 10 - Indian Springs and from 28 - Hampshire Rcks.
Temporal Representation: Samples were collected from site 10 on 3/14/2003, 4/3/2004, 6/12/2004, 1/7/2006, and 7/8/2006; and from site 28 on 8/6/2005, 2/4/2006, 6/10/2006, and 1/6/2007.
Environmental Conditions:
QAPP Information: Samples were collected and analyzed in accordance with Water Monitoring Quality Assurance Project Plan prepared for the Yuba Watershed Monitoring Committee (Revision 1.3) dated June 30, 2008.
QAPP Information Reference(s):
 
Line of Evidence (LOE) for Decision ID 93804, Iron
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 59405
 
Pollutant: Iron
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 9
Number of Exceedances: 0
 
Data and Information Type: Fixed station physical/chemical (conventional plus toxic pollutants)
Data Used to Assess Water Quality: None of the nine samples exceeded the recommended criteria of 1,000 ug/L.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: National Recommended Water Quality Criteria Continuous Concentrations are intended protect freshwater aquatic organisms from chronic exposures and are expressed as 4-day average concentrations. The recommended criteria is 1,000 ug/L.
Guideline Reference: National Recommended Water Quality Criteria. United States Environmental Protection Agency. Office of Water. Office of Science and Technology
 
Spatial Representation: Samples were collected from station 10 - Indian Springs and from site 28 - Hampshire Rcks.
Temporal Representation: Samples were collected from site 10 on 3/14/2003, 4/3/2004, 6/12/2004, 1/7/2006, and 7/8/2006. Samples were collected from site 28 on 8/6/2005, 2/4/2006, 6/10/2006, and 1/6/2007.
Environmental Conditions:
QAPP Information: Samples were collected and analyzed in accordance with Water Monitoring Quality Assurance Project Plan prepared for the Yuba Watershed Monitoring Committee (Revision 1.3) dated June 30, 2008.
QAPP Information Reference(s): Quality Assurance Project for Yuba Watershed Monitoring Committee, Revision 1.3.
 
 
DECISION ID
93531
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: Nitrate
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of four samples exceed the MCL specified in Title 22 of the California Code of Regulations for MUN.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that:

1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of four samples exceed the MCL specified in Title 22 of the California Code of Regulations for MUN and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 93531, Nitrate
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 72684
 
Pollutant: Nitrate
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Total
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 4
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: None of the four samples exceeded the water quality objective for nitrate. The sample was reported as nitrate as nitrogen and converted before compared with the objective.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Water Quality Control Plan, Central Valley Region Sacramento River Basin and San Joaquin River Basin: At a minimum, water designated for MUN shall not contain concentrations of chemical constituents in excess of the MCL specified in Title 22 of the California Code of Regulations. The MCL for nitrate (as NO3) is 45 mg/L
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Samples were collected at SYRCL monitoring stations 38 - Plavada, 39 - Van Norden Dam, and 44 - Kingvale.
Temporal Representation: Samples were collected on 12/2/2006, 8/4/2007, and 7/7/2007.
Environmental Conditions:
QAPP Information: This data was collected under the Water Monitoring Quality Assurance Project Plan for the Yuba Watershed Council Monitoring Committee. qa12
QAPP Information Reference(s):
 
 
DECISION ID
87985
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: Oxygen, Dissolved
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Seventeen of the 126 samples exceed the water quality objective for COLD.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Seventeen of the 126 samples exceed the water quality objective for COLD and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 87985, Oxygen, Dissolved
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 59389
 
Pollutant: Oxygen, Dissolved
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 126
Number of Exceedances: 17
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Seventeen of the 126 daily averaged samples exceeded the water quality objective for dissolved oxygen in this water body.
Data Reference: Data for Various Pollutants at Placer County Utilities, 2005-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: From the Basin Plan, the minimum level for dissolved oxygen is 7 mg/L for waters designated as COLD.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Samples collected at the following sites: 10 - Indian Springs 28 - Hampshire Rcks 38 - Plavada 39 - Van Norden Dam 41 - Yuba HeadH20 43 - Rainbow Bend 44 - Kingvale 58 - Lola Montez Br 61 - Abv DSPUD discharge 62 - Blw DSPUD discharge
Temporal Representation: Samples collected between 1/13/2001 and 8/9/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)
QAPP Information Reference(s):
 
 
DECISION ID
100369
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: Specific Conductivity
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the 127 samples exceed the Criteria/Objective.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 127 samples exceed the Criteria/Objective and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 100369, Specific Conductivity
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 59388
 
Pollutant: Specific Conductivity
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Municipal & Domestic Supply
 
Number of Samples: 127
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: None of the 127 daily averaged samples exceeded the water quality objective for electrical conductivity in this water body.
Data Reference: Data for Various Pollutants at Placer County Utilities, 2005-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The secondary MCLs for electrical conductivity provide a range of values including a recommended level (900 uS/cm), upper level (1600 uS/cm) and a short-term level (2200 uS/cm). The 'recommended' level of 900 uS/cm was used as it is intended to be protective of all drinking water uses.
Objective/Criterion Reference: Secondary Maximum Contaminant Levels and Compliance. CCR Title 22 section 64449.
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Samples collected at sites the following sites: 10 - Indian Springs 28 - Hampshire Rcks 38 - Plavada 39 - Van Norden Dam 41 - Yuba HeadH20 43 - Rainbow Bend 44 - Kingvale 58 - Lola Montez Br 61 - Abv DSPUD discharge 62 - Blw DSPUD discharge
Temporal Representation: Samples collected between 1/13/2001 and 8/9/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)
QAPP Information Reference(s):
 
 
DECISION ID
88041
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: Temperature, water
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of the 270 samples exceed the Evaluation Guideline.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of 270 samples exceed the Evaluation Guideline and this does not exceed the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list because applicable water quality standards are not being exceeded.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 88041, Temperature, water
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 72685
 
Pollutant: Temperature, water
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 270
Number of Exceedances: 0
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: None of the 270 samples exceeded the evaluation guideline for temperature in this water body (SYRCL, 2010).
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: The natural receiving water temperature of intrastate waters shall not be altered unless it can be demonstrated to the satisfaction of the Regional Water Board that such alteration in temperature does not adversely affect beneficial uses. In determining compliance with the water quality objectives for temperature, appropriate averaging periods may be applied provided that beneficial uses will be fully protected (Central Valley Regional Board Basin Plan, Pg. III-8.00, Water Quality Objectives).
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: The lethal temperature threshold for Steelhead adult migration and holding and juvenile growth and rearing is 24 degrees Celsius. (Carter, 2008).
Guideline Reference: Effects of Temperature, Dissolved Oxygen/Total Dissolved Gas, Ammonia, and pH on Salmonids. Implications for California's North Coast TMDLs. California Regional Water Quality Control Board, North Coast Region
 
Spatial Representation: Samples were collected at the following locations: SYRCL monitoring station 10, Indian Springs SYRCL monitoring station 28, Hampshire Rcks SYRCL monitoring station 38, Plavada SYRCL monitoring station 39, Van Norden Dam SYRCL monitoring station 41, Yuba HeadH20 SYRCL monitoring station 43, Rainbow Bend SYRCL monitoring station 44, Kingvale SYRCL monitoring station 58, Lola Montez Br SYRCL monitoring station 61, Abv DSPUD discharge SYRCL monitoring station 62, Blw DSPUD discharge
Temporal Representation: Samples were collected monthly from 1/13/2001 to 8/9/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)
QAPP Information Reference(s):
 
 
DECISION ID
93855
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: Zinc
Final Listing Decision: Do Not List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: Do Not List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Zero of two samples exceed the California Toxics Rule (CTR) criterion continuous concentrations to protect aquatic life in freshwater for COLD.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification against placing this water segment-pollutant combination on the CWA section 303(d) List. This conclusion is based on the staff findings that:

1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Zero of two samples exceed the California Toxics Rule (CTR) criterion continuous concentrations to protect aquatic life in freshwater for COLD and this sample size is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating. A minimum of 16 samples is needed to determine if a beneficial use is fully supported using table 3.1.
4. Pursuant to Section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should not be placed on the section 303(d) list. The readily available data and information is insufficient to determine, with the power and confidence of the Listing Policy, the applicable beneficial use support rating.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 93855, Zinc
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 72687
 
Pollutant: Zinc
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 2
Number of Exceedances: 0
 
Data and Information Type: Non-fixed station physical/chemical (conventional + toxicants)
Data Used to Assess Water Quality: None of the two samples exceeded the water quality criteria for zinc.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: California Toxics Rule (CTR) lists criterion continuous concentrations (expressed as a 4-day average concentration) to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. If no hardness data were available, a hardness of 100 mg/L was used.
Guideline Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Spatial Representation: Samples were collected from station 10 - Indian Springs and from site 28 - Hampshire Rcks.
Temporal Representation: Samples were collected from site 10 on 3/14/2003 and from site 28 on 4/13/2002.
Environmental Conditions:
QAPP Information: Samples were collected and analyzed in accordance with Water Monitoring Quality Assurance Project Plan prepared for the Yuba Watershed Monitoring Committee (Revision 1.3) dated June 30, 2008.
QAPP Information Reference(s):
 
 
DECISION ID
93803
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: Copper
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2027
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.1 of the Listing Policy. Under section 3.1 a single line of evidence is necessary to assess listing status.

One line of evidence is available in the administrative record to assess this pollutant. Two of three samples exceed the California Toxics Rule (CTR) criterion continuous concentrations to protect aquatic life in freshwater for COLD.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3.Two of three samples exceed the California Toxics Rule (CTR) criterion continuous concentrations to protect aquatic life in freshwater for COLD and this exceeds the allowable frequency listed in Table 3.1 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 93803, Copper
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 72660
 
Pollutant: Copper
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: Not Recorded
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 3
Number of Exceedances: 2
 
Data and Information Type: Non-fixed station physical/chemical (conventional + toxicants)
Data Used to Assess Water Quality: Two of the three samples exceeded the water quality criteria for copper of 8.9 ug/L.
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: Waters shall not contain chemical constituents in concentrations that adversely affect beneficial uses.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline: California Toxics Rule (CTR) lists criterion continuous concentrations (expressed as a 4-day average concentration) to protect aquatic life in freshwater. The criterion in freshwater is hardness dependent for each sample and varies based on the ambient hardness during sampling. Section (b)(1) in CTR contains the hardness dependent formula for the metals criterion. No hardness data were available, a hardness of 100 mg/L was used for a criteria value of 8.9 ug/L.
Guideline Reference: Code of Federal Regulations 40 part 131.38 Establishment of numeric criteria for priority toxic pollutants for the State of California. 7/1/2011 Edition
 
Spatial Representation: Samples were collected from station 10 - Indian Springs.
Temporal Representation: Samples were collected from site 10 on 3/14/2003, 5/1/2004, and 9/11/2004.
Environmental Conditions:
QAPP Information: Samples were collected and analyzed in accordance with Water Monitoring Quality Assurance Project Plan prepared for the Yuba Watershed Monitoring Committee (Revision 1.3) dated June 30, 2008.
QAPP Information Reference(s):
 
 
DECISION ID
87987
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
Pollutant: pH
Final Listing Decision: List on 303(d) list (TMDL required list)
Last Listing Cycle's Final Listing Decision: List on 303(d) list (TMDL required list)(2016)
Revision Status Original
Sources: A Source Unknown
Expected TMDL Completion Date: 2027
Impairment from Pollutant or Pollution: Pollutant
 
Regional Board Conclusion: This pollutant is being considered for placement on the CWA section 303(d) List under section 3.2 of the Listing Policy. Under section 3.2 a single line of evidence is necessary to assess listing status..

One line of evidence is available in the administrative record to assess this pollutant. Sixteen of the 81 samples exceed the water quality objective.

Based on the readily available data and information, the weight of evidence indicates that there is sufficient justification in favor of placing this water segment-pollutant combination on the CWA section 303(d) List.

This conclusion is based on the staff findings that:
1. The data used satisfies the data quality requirements of section 6.1.4 of the Policy.
2. The data used satisfies the data quantity requirements of section 6.1.5 of the Policy.
3. Sixteen of the 81 samples exceed the water quality objective, and this exceeds the allowable frequency listed in Table 3.2 of the Listing Policy.
4. Pursuant to section 3.11 of the Listing Policy, no additional data and information are available indicating that standards are not met.
 
Regional Board Decision Recommendation: After review of the available data and information, RWQCB staff concludes that the water body-pollutant combination should be placed on the section 303(d) list because applicable water quality standards are exceeded and a pollutant contributes to or causes the problem.
 
State Board Review of Regional Board Conclusion and Recommendation:
 
State Board Decision Recommendation: After review of this Regional Board decision, SWRCB staff recommend the decision be approved by the State Board.
 
 
Line of Evidence (LOE) for Decision ID 87987, pH
Region 5     
Yuba River, South Fork (Headwaters to Spaulding, Lake)
 
LOE ID: 59390
 
Pollutant: pH
LOE Subgroup: Pollutant-Water
Matrix: Water
Fraction: None
 
Beneficial Use: Cold Freshwater Habitat
 
Number of Samples: 81
Number of Exceedances: 16
 
Data and Information Type: PHYSICAL/CHEMICAL MONITORING
Data Used to Assess Water Quality: Sixteen of the 81 daily averaged samples exceeded the water quality objective for pH in this water body (they were below 6.5).
Data Reference: Data in Yuba: metal, 2000-2007 and conventional, 2000-2010.
 
SWAMP Data: Non-SWAMP
 
Water Quality Objective/Criterion: From the Basin Plan, pH levels should not be lower than 6.5 or higher than 8.5.
Objective/Criterion Reference: Water Quality Control Plan for the California Regional Water Quality Control Board Central Valley Region, Sacramento and San Joaquin River Basins. 4th ed
 
Evaluation Guideline:
Guideline Reference:
 
Spatial Representation: Samples collected at the following sites: 10 - Indian Springs 28 - Hampshire Rcks 38 - Plavada 39 - Van Norden Dam 41 - Yuba HeadH20 43 - Rainbow Bend 44 - Kingvale 58 - Lola Montez Br 61 - Abv DSPUD discharge 62 - Blw DSPUD discharge
Temporal Representation: Samples collected between 1/13/2001 and 7/10/2010.
Environmental Conditions:
QAPP Information: CITIZEN WATER MONITORING QUALITY ASSURANCE PROJECT PLAN FOR THE YUBA WATERSHED MONITORING COMMITTEE (June 30, 2008)