Vendor | Equipment Name | Leak Rate/Threshold/Max Pipeline Capacity |
---|---|---|
Estabrook EZY CHEK Systems (originally listed as Horner EZY CHEK) | EZY-Chek Manual Line Leak Detector (for Rigid Pipelines) | 0.1 gph/0.05 gph/426 gallons |
EZY-Chek Manual Line Leak Detector (for Flexible Pipelines) | 0.1 gph/0.05 gph/101 gallons | |
EZY-Chek II Automatic Line Leak Detector | 0.1 gph/0.05 gph/129 gallons | |
Hansa Consult of North America, LLC. | HCNA Pipeline Leak Detection System, Version 2.1 | 0.068 gph /0.034 gph/5,000 gallons |
Leak Detection Technologies, Inc. | MDleak Enhanced Leak Detection Method (line tightness test method) | 0.005 gph / when the chemical marker detected exceeds the background level outside of the pipeline / Not limited by capacity |
Leighton O’Brien Pty. Ltd. | Quantitative Wet Line Test PM2 (for Rigid and Flexible Pipelines) | 0.1 gph/0.05 gph/481 gallons |
Quantitative Dry Line Test PM2 (for Rigid and Flexible Pipelines) | 0.1 gph/0.05 gph/481 gallons | |
Linde Services, Inc. (formerly Praxair Services, Inc. and Tracer Research Corp.) | Tracer Tight Line Test | 0.1 gph and 0.005gph/A pipeline system should not be declared tight when tracer chemical is detected outside of the pipeline/Not limited by capacity |
MassTech International Ltd. | ML3P Line Leak Detection System | 0.1 gph/0.05 gph/172 gallons |
ProTank, Inc. | LTH-5000 Line Tester | 0.1 gph/0.05 gph/40 gallons |
LTP-5000 Line Tester | 0.1 gph/0.05 gph/41 gallons | |
Purpora Engineering, LLC (originally listed as Heath Consultants, Inc.) | Petro Tite Line Tester | 0.1 gph/0.05 gph/129 gallons |
Purpora Engineering, LLC (originally listed as Heath Consultants, Inc.) | Petro Tite Line Tester (for Flexible Pipelines) | 0.1 gph/0.05 gph/49.6 gallons |
Tanknology - NDE | Proline Test Series III, Version 1.0 Line Test | 0.1 gph/0.05 gph/41 gallons |
PTK-88 | 0.1 gph/0.05 gph/40 gallons | |
TLD-1 Line Test | 0.1 gph/0.05 gph/172 gallons | |
TLD-1 Line Test (Flexible Pipelines) | 0.1 gph/0.05 gph/119.4 gallons | |
Training and Services Corp. (originally listed as Hasstech) | AcuRite (for Rigid and Flexible Pipelines) | 0.1 gph/0.01 gph/150 gallons |
Triangle Environmental, Inc. | TEI Model LT-3, Version 1.0 | 0.1 gph/0.05 gph/80 gallons |
United Testing Systems | U.T.S. 6000 Line Tester | 0.1 gph/0.03 gph/ 44 gallons |
Western Environmental Resources | Model PLT-100R | 0.1 gph/0.05 gph/80 gallons |