LG 113 RESOURCES
- LG 113 Home Page
- Distribution Letter
- Disclaimer
- Equipment Type:
- New! Recent Equipment Type Additions/Revisions
- VPH Methods
- Test Method Index
- Acceptable E85 Leak Detection
- Acceptable Biodiesel Leak Detection
- Leak Detection Equipment Review List
- Acceptable Test Protocols
- Glossary of Terms
- Monitoring System Certification
- Work Group
- Policy Memoranda:
- Policy Memo #1
- Policy Memo #2
- Policy Memo #3
- Maintenance Checklists:
UST Program - LG 113 - Statistical Inventory Reconcilation Test Methods (Quantitative)
Statistical Inventory
Reconciliation Test Methods
(Quantitative)
Click on the vendors specific Equipment Name to go to that Listing.
Vendor | Equipment Name | Leak
Rate/Threshold / Max Tank Capacity |
Clearstone Engineering Ltd. |
0.2 gph/0.10 gph/30,000 gallons for single tanks and 45,000 gallons for manifolded tanks |
|
Computerizing, Inc. | Computank, Version 3.0 | 0.1 gph/0.05 gph/18,000 gallons |
EviroSIR LLC | EnviroSIR Version 1.0 | 0.2 gph/0.15
gph/45,000 gallons 0.1 gph/0.05 gph/45,000 gallons |
Horner Products, Inc. | SIR PRO 1 Versions 3.0 | 0.2 gph/0.1 and 0.16gph/45,000 gallons |
SIR PRO 1 Versions 4.0 | 0.1 gph/0.05 gph/33,000 gallons | |
Fairbanks Environmental Ltd | Wetsock Wizard Version 4.4 | 0.2 gph/0.1 gph/45,000 gallons |
Leighton O'Brien Pty. Ltd. | Monitor / REDONE | gph/0.1 gph/0.05 gph/33,675 gallons for single tanks, and 60,000 gallons for manifolded tanks |
National Environmental, LLC | Tanknetics SIR, Version 2.1 | 0.2 gph/0.10 gph/45,000 gallons 0.1 gph/0.05 gph/45,000 gallons |
Simmons Corp. | SIR 5.7 | 0.1 gph/0.05 gph/18,000 gallons |
SIR 5.7 LM | 0.2 gph/0.10
gph/60,000 gallons 0.1 gph/0.05 gph/60,000 gallons |
|
SIR International, Inc. | Mitchell's SIR Program Versions 2.6, 2.7 | 0.1 gph/0.05 gph/45,000 gallons |
SIR Monitor (originally listed as Environmental Management Technologies) | SIR Monitor | 0.1 gph/0.05 gph/18,000 gallons |
Sir Phoenix, Inc. | SIR Phoenix | 0.1 gph/0.05 gph/18,000 gallons |
SIR Phoenix LEOMA V01.50 | 0.2 gph/0.01 gph/18,000 gallons for single tanks, and 45,000 gallons for manifolded tanks | |
TeleData, Inc. | TankMate, Versions 3.12, 3.20, 4.1 | 0.1 gph/0.05 gph/60,000 gallons |
TotalSIR | TotalSIR Version 1.0 | 0.2 gph/0.1 and 0.16 gph/45,000 gallons |
TotalSIR Version 2.0 | 0.2 gph/0.10
gph/45,000 gallons 0.1 gph/0.05 gph/45,000 gallons |
|
Veeder-Root (originally listed as Entropy Limited) | Precision Tank Inventory Control System, Revision 90 | 0.1 gph/0.05 gph/22,500 gallons |
Veeder-Root (originally listed as USTMAN Industries, Inc.) | USTMAN SIR 1.91 | 0.1 gph/0.1 gph/18,000 gallons |
USTMAN SIR, Version 94.1 | 0.1 gph/0.05 gph/30,000 gallons | |
USTMAN SIR, Versions 95.2, 95.2A, 95.2B | 0.1 gph/0.05
gph/60,000 gallons (Version 95.2) 0.2 gph/0.1 gph/60,000 gallons (Version 95.2A) 0.2 gph/0.16 gph/60,000gallons (Version 95.2B) |
|
Veeder-Root (originally listed as Watson Systems, Inc. and EnviroQuest Technologies Limited) | Watson SIRAS Software System Versions 2.0, 2.8.3 | 0.2 gph/0.1
gph/30,000 gallons 0.1 gph/0.05 gph/30,000 gallons |
Warren Rogers Associats, Inc. | WRA Statistical Inventory Analysis, Version 5.1 | 0.1 gph/0.05 gph/18,000 gallons |
WRA Statistical Inventory Analysis, Version 5.2 | 0.1 gph/0.05 gph/36,000 gallons |