Click on the vendors specific Equipment Name to go to that Listing.

Vendor Equipment Name Operating Principle
Beaudreau Electric Marketing, LLC Model MPC100 Controller with Models DCS140L, DCS140NL Liquid Sensors and Model DCS140D Discriminating Liquid Sensor
float switch
Caldwell Systems Corp. Tank Manager Liquid Sensor, Version TMLIQ ultrasonic
Containment Solutions, Inc. (originally listed as Fluid Containment which was formerly O/C Tanks) DDAS 910 Discriminating Sensor for Dry Annular Spaces; DCBS 900 Discriminating Sensor for Collars, Bulkheads, Sumps capacitance change
FOVF 600B, FOVF 600S Non-Discriminating Sensors for High Level Overfill (Brass, Steel); FCBS 700 Non-Discriminating Sensors for Collars, Bulkheads, Sumps; FDAS 710 Non-Discriminating Sensor for Dry Annular Spaces; FHRB 810 Non-Discriminationg Sensor for Reservoirs float switch
EBW, Inc. AUTO-STIK Sensors LS-5, LS-7, LS-10, LS-15, LS-20, LS-35, LS-3A, LS-30A float switch
Franklin Fueling Systems (Originallly listed as Beaudreau Electronics, Inc.) Model FFS 404-4 Controller with Models S404 and S406 Liquid Level Sensors float switch (Model S404), refractive index of liquids (Model S406)
Fuel Oil Systems Gems LS-750, Innovative Solutions L176-0108-0803 (Kele FS7SS), and Madison M4602-XXXX Sensors with Fuels Oil Systems Console - FOS-0160-1, software version 001 float switch
Franklin Fueling Systems Incon TS-1001/2001, TS-5, TS-550, TS-5000, TS-550 evo, and TS-5000 evo with FMP-HFS Horizontal Float Switch, FMP-HLS High Level Float Switch, FMP-HIS Hydrostatic Interstitial Float Sensor, and FMP-HIS-XL Hydrostatic Interstitial Float Sensor float switch
Incon TS-1001/2001, TS-5,TS-550, TS-5000, TS-550 evo and TS-5000 evo with FMP-DDS Discriminating Dispenser Sump Sensor and FMP-DTS Discriminating TurbineĀ  Sump Sensor float switch
Incon TS-1001/2001, TS-5, TS-550, TS-5000, TS-550 evo, and TS-5000 evo with FMP-DIS Discriminating Interstitial Sensor and FMP-EIS Electro-Optical Interstitial Sensor conductivity, electro-optic
S940 Alarm Console with TSP-HFS Horizontal Float Switch Sensor, TSP-HLS High Level Sensor, TSP-UHS Universal Hydrostatic Sensor, and TSP-ULS Universal Liquid Sensor float/reed switch
Incon TS-1001/2001, TS-5, TS-550, TS-5000, TS-550 evo, TS-5000 evo, EVO400, EVO200, and S940 Alarm Console with FMP-ULS Universal Liquid Sensor, FMP-UHS Universal Hydrostatic Sensor, FMP-ULS-C Universal Liquid Sensor Chemical, FMP-ULS-PS Universal Liquid Sensor Position Sensitive sensors float/reed switch
Franklin Fueling Systems EVO400, EVO200 with FMP-DDS-U Discriminating Dispenser Sump Sensor and FMP-DTS-U Discriminating Turbine Sump Sensor float switch
Franklin Fueling Systems EVO400, EVO200 with FMP-DIS-U Discriminating Interstitial Sensor and FMP-EIS-U Electro-Optical Interstitial Sensor conductivity, electro-optic
Franklin Fueling Systems EVO400, EVO200 with FMP-HIS-U Hydrostatic Interstitial Float Sensor, and FMP-HIS-XL-U Hydrostatic Interstitial Float Sensor float switch
Franklin Fueling Systems (Originallly listed as INCON Intelligent Controls, Inc.) Tank Sentinel TS-1000EFI, TS-1001/TS-2001, and TS-5xxx Series with TSP-DIS BriteSensor; Tank Sentinel TS-1000/TS-2000, TS-1001/TS-2001, and TS-5xxx Series withTSP-EIS Standard Sensor; Tank Sentinel TS-1000/TS-2000 with TSP-PS Liquid Contact Sensor opto-electric
Franklin Fueling Systems (Originallly listed as INCON Intelligent Controls, Inc.) Tank Sentinel TS-1000EFI , TS-1001/TS-2001, and TS-5xxx Series with TSP-HIS BriteSensor; Tank Sentinel TS-1000/TS-2000, TS-1001/TS-2001, and TS-5xxx Series with TSP-HLS Standard Sensor and TSP-ULS Standard Sensor magnetic switch
Franklin Fueling Systems (Originallly listed as Beaudreau Electric, Inc.) Model FFS 404-4 Controller with Models S404 and S406 Liquid Level Sensors float switch (Model S404) refractive index of liquids (Model S406)
Fueling and Service Technologies, Inc. (FASTECH) (Originallly listed asBeaudreau Electric, Inc.) Model DFR-1 Liquid Level Switch, Models EOS100, 510 and 516 Discriminating Sensors with Models 500 and 500C Controllers, Model 522 Remote Monitoring System, Model 522T Monitoring System, and ESite Monitoring System float switch (Model DRF-1), refractive index of liquids (Model EOS100), polymer strip, hydrocarbon-only (Model 510), optical sensor and conductivity (Model 516)
Gems Sensors, Inc. (originally listed as Warrick Controls, Inc.) DMS-47X-X-X(-X), DMS-57X-X-X(-X) Monitoring Panels
Models DLP-1-NC, DLP-2-NC, DLP-2-NO Sensors
float switch
Gems Sensors, Inc. (originally listed as Warrick Controls, Inc.) Model DFP-25 Sensor product solubility
Morrison Bros. Co. 924LS, 924 and 925 Sensor for use with the 918AC, 918S, 918D and 918Q Alarm Console float switch
Oklahoma Environmental Services (originally listed as Arizona Instrument Corp., then NESCO, then Phoenix Technologies) Soil Sentry Liquid 330(17-330-A/17-330-B), TLM-830, ENCOMPASS APAM
Probes 17-141A, 17-142A, 17-143A, 17-144A 
refraction
OMNTEC Mfg., Inc. Controller Models OEL 8000 11, K-OEL 8000 11 with Liquid level Sensors BX-L, BX-LS, BX-LWF,
BX-RES
optical sensor
Controller Models OEL 8000 11, K-OEL 8000 11 with Liquid level Sensors BX-PDS, BX-PDWF,
BX-PDWS
optical sensor, conductivity
Controller Models Series LPD, LU, OEL8000 with Sensors L-LL-R-1, LS-ASC, PDS-ASC, PDWS-1, PDWF-1
refractive index of liquids (all), electrical conductivity (PDS-ASC, PDWS-1, PDWF -1)
Controller Models OEL 8000 III (Proteus B, K, and X Consoles) with Liquid level Sensors BX-PDS, BX-PDWF, BX-PDWS, BX-LS, BX-LV, BX-LWF, BX-RES optical sensor (all), electrical conductivity (PD-PDS, BX-PDWF, and BX-PDWS)
OPW Fuel Management Systems. iSite, iTouch, and EECO Series Fuel Management Systems with OPW Intelligent Sensor (and Company Equivalent): 30-231-S, 30-0230-S (30-3221-1A/1B, Q003-009); 30-0231-L (30-3221-1); 30-0232-D-10/D-20/D-10B/D-20B (Q0003-001/002); and the 924B Sump Sensor float switch
OPW Fuel Management Systems
(originally listed as Emco Electronics, Tuthill Transfer Systems)
EECO System Leak Sensor II, Leak Sensor Jr. Thermistor and Proximity probes thermal conductivity, proximity switch
EECO 2000, 3000, Leak Sensor II, Leak Sensor Jr. Systems Q0001-005 Interstitial Space Flood Sensor, and
EECO 1500, 2000, 3000 Systems
Q0003-005 Wet Interstitial Sensor
float switch
EECO 1500, 2000, 3000 Systems
Q0003-001 Discriminating Dispenser Pan Sensor,
Q0003-002 Discriminating STP Sump Sensor,
Q0003-003 Discriminating Interstitial Sensor,
Q0003-006 Liquid Only Interstitial Sensor,
Q0003-009 Liquid Float Sensor
float switch and polymer strip
(Q0003-001, Q0003-002),
optical prism and conductivity (Q0003-003),
optical prism (Q0003-006),
float switch (Q0003-009)
OPW Fuel Management Systems
(originally listed as Petro Vend, Inc.)
Petrosentry IV, Petrosentry VIII, SiteSentinel thermal conductivity (Liquid Sensor)
float switch (Universal Sump Sensor, Universal Reservoir Sensor)
PermAlert LiquidWatch Leak Detection System LW64-IS with PHLR-LW and PHLR-P-LW Hydrocarbon Probes Product permeable, magnetic membrane switch
PAL-AT Models AT20C, AT50C, AT40K, PHL Hydrocarbon Sensor electrical conductivity
e. PAL-AT Models AT20C, AT30C, AT50C, AT75C, AT20K, AT30K, AT40K, AT80K with PHLR-S/L and PHLR-P-S/L Hydrocarbon Probes Product permeable, magnetic membrane switch
TankWatch Models PHM10, PHMS,
Combination Hydrocarbon/Water Probe, Hydrocarbon Probe
electrical conductivity
Pneumercator Company, Inc. LC 1000 Series, E-14-29, E-700-1, LDE-700, LDE-740, TMS 2000, TMS 3000 with Level Sensor Models LS600AB, RSU800 float switch
LDE 700, LDE 740, LDE 9000
Sensor Probe Models 9-901, 9-902, 9-903
capacitance
TMS 2000, TMS 3000 with ES820-100 Non-Discriminating Liquid Sensor, ES820-200 Discriminating Liquid Sensor optical sensor
LC2000, TMS 2000, TMS 3000 with ES825-100F, 100XF, 100CF Non-Discriminating Liquid Sensor, ES825-200F, 200FX Discriminating Liquid Sensor optical sensor
TMS 1000, TMS 2000W (wireless) with ES825-300F, 300XF, 300CF Non-Discriminating Liquid Sensor, ES825-400F, 400XF Discriminating Liquid Sensor optical sensor, electrical conductivity
LC 1000 Series, LC 2000 Series, E-14-29, E-700-1, LDE-700, LDE-740, TMS 2000,TMS 2000W, TMS 3000 with Level Sensor Models LS600 Series, LS600LD Series, LS610 float switch
LC 1000 Series, LC 2000 Series, E-14-29, E-700-1, LDE-700, LDE-740, TMS 1000 Series, TMS 2000, TMS 2000W, TMS 3000 with Level Sensor Models RSU800, RSU810 float switch
Preferred Utilities Manufacturing Corporation TG-EL-D3 Controller with HD-A1 Sensor optical sensor, electrical conductivity
Preferred Utilities Manufacturing Corporation TG-EL-D4A Fuel Sentry Control Unit, HD-A2-C Optical Discriminating Sensor optical sensor
Robertshaw Industrial Products Centeron High Level Alarm System (SM Series Switch Monitor with Centeron FSL Series Float Switches: Models *FSL AAA BB CC DD EE 0 and *FSL AAA BB CC DD EE C) reed switch
Ronan Engineering Co. Ronan Controller Models X76S; X76VS; X76LVC; TRS76; X76ETM, LVCS; X76CTM-N4; X76ETM-4X; X76-4X, -3, -6, -9, -12; X76AST-4X
Ronan Sensors LS-3 N.C.; LS-3 N.O.; LS-30; LS-7; HVA; LS-3SS; LS-1
float switch
S Bravo Systems, Inc. Model B-2000 Shallow Steel Dispenser Containment System, Model B-8600 Aboveground/Marina Steel Dispenser Containment System float switch
Simone Engineering, Inc. Magnetrol Model 918 Ultrasonic Point Level Switch with ABB Automation Freelance 2000 Control System electrical conductivity, ultrasonic
Tidel Engineering, Inc. EMS-3500 Containment Sump Probes Part 301-0642,
Tidel Detector No. 301-0752-001
electrical conductivity/hydrocarbon sensitive polymer
(Part No. 301-0635)
magnetic switch/float and hydrocarbon sensitive polymer (Part No. 301-0642)
float switch
(Part No. 301-0752-001)
Tyco Thermal Controls LLC
(originally listed as Raychem Corp.
TraceTek Alarm and Locator Modules TT502, TT5000, TT3000 Fuel Sensing Cable
electrical conductivity
Tyco Thermal Controls LLC TraceTek Alarm and Locator Modules with TT-FFS Fast Fuel Sensor
electrical conductivity
Universal Sensors and Devices, Inc. Leak Alert System
Models LAL-100, LA-01, LA-02, LA-04, LA-X4, LA-08, DLS-01, LS-20, LS-36, LS-70, CATLAS
Liquid Sensor LALS-1
thermal conductivity
Veeder-Root (originally listed as Gilbarco Environmental Products and later as Marconi Commerce Systems) PA02590XXX000 (Same as Veeder-Root 0794390-401, 404, 407, 409), PA02591144000 (Same as Veeder-Root 0794390-420, 460), PA02592000010 (Same as Veeder-Root 0794380-206)
float switch
Veeder-Root (originally listed as Marley Pump Co.) Red Jacket Electronics RE400-179-5 to RE400-199-5 Combination High Level/Low Level Sensor, RE400-042-5 Hydrostatic Sensor,  Red Jacket PPM 4000 with Optical Liquid Discrimination Sensor float switch (RE400-179-5 to RE400-199-5, RE400-042-5)
optical sensor (PPM4000)
Red Jacket Electronics RE400-058-5, RE400-059-5, RE400-147-5, RE400-148-5 Overfill Sensor, RE400 111-5 Sump Sensor, RE400-203-5 Optical Liquid Discrimination Sensor, RE400-204-5 Dispenser Pan Monitor, RE400-180-5 Liquid Refraction Sensor float switch (RE400-058-5, RE400-059-5, RE400-147-5, RE400-148-5, RE400-111-5), electrical conductivity and optical (RE400-203-5),
conductive polymer (RE400-204-5),
optical (RE400-180-5)
Veeder-Root ILS-250, ILS-350, TLS-250i, 250i Plus, 300, 300C, 300i, 300PC, TLS-350 Series, TLS-450 Series, TLS-4 8601 Series, Red Jacket ProMax and ProPlus Interstitial Liquid Sensor for Fiberglass Tanks (794390-401, 404, 407, 409) Interstitial Liquid Sensor for Steel Tanks (794390-420, 460) Liquid Sensor for Sumps 794390-206 float switch
TLS-350 Series, TLS-450 Series, TLS-4 8601 Series, Red Jacket ProMax with Interstitial Liquid Sensor 794380-341, Dispenser Pan Sensor 794380-320, Discriminating Containment Sump Sensor 794380-350, Discriminating Fibretrench Sensor 794380-360, 361, 362 capacitance change/ultrasonic (794380-341)
electrical conductivity/ultrasonic (794380-320, 350, 360, 361, 362)
TLS-300, 300i, TLS-350 Series, TLS-450 Series, TLS-4 8601 Series, Red Jacket ProMax and ProPlus with Discriminating Dispenser Pan Sensor 794380-322, Discriminating Containment Sump Sensor 794380-352 product permeable, reed switch/float
Dispenser Pan Sensor (847990-001) and Differentiating Dispenser Pan Sensor (847990-002) With Dispenser Control Interface product permeable, reed switch/float
TLS-350 Series, TLS-300 series, TLS-450 Series, TLS-4 8601 Series, EMC Series, EMC Basic, Red Jacket ProMax and ProPlus with Single Stage Hydrostatic Sensor 794380-301 and Dual Stage Hydrostatic Sensors 794380-302, 303 float switch
TLS-300C, 300i, 300PC, 350, 350PC, 350R, 350RPC, TLS-450 Series, ILS-350, TLS-4 8601 Series, Red Jacket ProMax and ProPlus with Solid-State Pan/Sump Sensor 794380-321, 351, Piping Sump Sensor 794380-208, 209, Micro Sensor 794380-340 product permeable,
ultrasonic/float switch
TLS-350, 350R Series, TLS-450 Series, TLS-4 8601 Series, Red Jacket ProMax and ProPlus Series with Discriminating Interstitial Sensor 794380-343, Micro Sensor 794380-344 optical sensor and conductivity
(794380-343)
optical sensor
(794380-344)
TLS-350, 350R Series, TLS-450 Series, TLS-4 8601 Series, Red Jacket ProMax with Interstitial Sensor 794380-345 optical sensor
ILS-350, TLS-300 Series, TLS 350 Series, TLS-450 Series, TLS-4 8601 Series, EMC Series, EMC Basic, Red Jacket ProMax and ProPlus with Position Sensitive Sensor 794380-323 float switch
TLS-300 Series, TLS-350 Series, TLS-450 Series, TLS-4 8601 Series, EMC Series, EMC Basic, Red Jacket ProMax and ProPlus withFloat Sensor 794380-430, float switch
TLS-350 Series, TLS-450 Series, TLS-4 8601 Series, EMC, EMC-PC, EMC Enhanced, EMC-PC Enhanced, and Red Jacket ProMax with Magnetostrictive Sump Sensor Series 857060-xxx and 857080-xxx* magnetostrictive probe with dual floats
ILS-350, TLS-300 Series, TLS-450 Series, TLS-4 8601 Series, EMC, EMC-Series, and Red Jacket ProMax, Red Jacket ProPlus with Single-Point Mini Hydrostatic Sensor 794380-304 reed switch
TLS-4; TLS-4B; TLS-300, 300C, 300i, 300PC; TLS-350, 350PC, 350R, 350R-PC; TLS-450 Series; Red Jacket ProMax, ProPlus and ProPlusPC with Position Sensitive Interstitial Sensor 794380-333 float/reed switch
8601 Series, 8600 Series, and TLS-3xx Series with Interstitial Liquid Sensor for Fiberglass Tanks 794390-409 float switch
 
 

.